Airborne Particulate Matter in School Classrooms of Northern Italy

Sabrina Rovelli    
Andrea Cattaneo    
Camilla P. Nuzzi    
Andrea Spinazzè    
Silvia Piazza    
Paolo Carrer and Domenico M. Cavallo    

Resumen

Indoor size-fractioned particulate matter (PM) was measured in seven schools in Milan, to characterize their concentration levels in classrooms, compare the measured concentrations with the recommended guideline values, and provide a preliminary assessment of the efficacy of the intervention measures, based on the guidelines developed by the Italian Ministry of Healthand applied to mitigate exposure to undesirable air pollutants. Indoor sampling was performed from Monday morning to Friday afternoon in three classrooms of each school and was repeated in winter 2011?2012 and 2012?2013. Simultaneously, PM2.5 samples were also collected outdoors. Two different photometers were used to collect the PM continuous data, which were corrected a posteriori using simultaneous gravimetric PM2.5 measurements. Furthermore, the concentrations of carbon dioxide (CO2) were monitored and used to determine the Air Exchange Rates in the classrooms. The results revealed poor IAQ in the school environment. In several cases, the PM2.5 and PM10 24 h concentrations exceeded the 24 h guideline values established by the World Health Organization (WHO). In addition, the indoor CO2 levels often surpassed the CO2 ASHRAE Standard. Our findings confirmed that important indoor sources (human movements, personal clouds, cleaning activities) emitted coarse particles, markedly increasing the measured PM during school hours. In general, the mean PM2.5 indoor concentrations were lower than the average outdoor PM2.5 levels, with I/O ratios generally <1. Fine PM was less affected by indoor sources, exerting a major impact on the PM1?2.5 fraction. Over half of the indoor fine particles were estimated to originate from outdoors. To a first approximation, the intervention proposed to reduce indoor particle levels did not seem to significantly influence the indoor fine PM concentrations. Conversely, the frequent opening of doors and windows appeared to significantly contribute to the reduction of the average indoor CO2 levels.

 Artículos similares

       
 
Constantini Samara    
This article presents the distribution of the dithiothreitol-based (DTT) redox activity of water-soluble airborne particulate matter (PM) from two urban sites in the city of Thessaloniki, northern Greece in four size ranges (<0.49, 0.49?0.97, 0.97?3.0... ver más
Revista: Atmosphere

 
Muhammad Abu-Elmagd, Mansour A. Alghamdi, Magdy Shamy, Mamdouh I. Khoder, Max Costa, Mourad Assidi, Roaa Kadam, Haneen Alsehli, Mamdooh Gari, Peter Natesan Pushparaj, Gauthaman Kalamegam and Mohammed H. Al-Qahtani    
-

 
Giovanni Lonati, Senem Ozgen, Giovanna Ripamonti and Stefano Signorini    
Cyclists might experience increased air pollution exposure, due to the proximity to traffic, and higher intake, due to their active travel mode and higher ventilation. Several local factors, like meteorology, road and traffic features, and bike lanes fea... ver más
Revista: Atmosphere

 
Ying-Yi Chen, Fung-Chang Sung, Mei-Lien Chen, I-Fang Mao and Chung-Yen Lu    
Indoor air pollution is an increasing health concern, especially in enclosed environments such as underground subway stations because of increased global usage by urban populations. This study measured the indoor air quality of underground platforms at 1... ver más

 
Daniel Dunea, Stefania Iordache and Alin Pohoata    
The overall objective of this research was to study children?s respiratory illness levels in Targoviste (Romania) in relationship to the outdoor concentrations of airborne particulate matter with an aerodynamic diameter below 2.5 µm (PM2.5). We monitored... ver más