Redirigiendo al acceso original de articulo en 15 segundos...
ARTÍCULO
TITULO

Indoor Air Quality in the Metro System in North Taiwan

Ying-Yi Chen    
Fung-Chang Sung    
Mei-Lien Chen    
I-Fang Mao and Chung-Yen Lu    

Resumen

Indoor air pollution is an increasing health concern, especially in enclosed environments such as underground subway stations because of increased global usage by urban populations. This study measured the indoor air quality of underground platforms at 10 metro stations of the Taipei Rapid Transit system (TRTS) in Taiwan, including humidity, temperature, carbon monoxide (CO), carbon dioxide (CO2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), ozone (O3), airborne particulate matter (PM10 and PM2.5), bacteria and fungi. Results showed that the CO2, CO and HCHO levels met the stipulated standards as regulated by Taiwan?s Indoor Air Quality Management Act (TIAQMA). However, elevated PM10 and PM2.5 levels were measured at most stations. TVOCs and bacterial concentrations at some stations measured in summer were higher than the regulated standards stipulated by Taiwan?s Environmental Protection Administration. Further studies should be conducted to reduce particulate matters, TVOCs and bacteria in the air of subway stations.

Palabras claves

 Artículos similares

       
 
ABDEL FATTAH A. QARAMAN, MAHER ELBAYOUMI, KHALID J. KHADOURA     Pág. Page:37 - 48Abstract
The indoor environmental quality (IEQ) in university buildings highly affect the health of students which they may experience a series of non-specific symptoms from being in that building. This paper aims to estimate the prevalence of sick building syndr... ver más

 
Sungroul Kim, Jungeun Lee, Sujung Park, Guillaume Rudasingwa, Sangwoon Lee, Sol Yu and Dae Hyun Lim    
Various studies have indicated that particulate matter <2.5 µm (PM2.5) could cause adverse health effects on pulmonary functions in susceptible groups, especially asthmatic children. Although the impact of ambient PM2.5 on children?s lower respiratory he... ver más

 
Nikolaos Barmparesos, Margarita Niki Assimakopoulos, Vasiliki D. Assimakopoulos, Nikolaos Loumos, Maria Aliki Sotiriou and Athanasios Koukoumtzis    
This paper presents experimental results from a typical school building in Athens, equipped partly with a green roof system (GRS). Environmental monitoring took place in six classrooms located both under the concrete roof and the GRS sectors as well as i... ver más
Revista: Atmosphere

 
Nuno Canha, Joana Lage, Catarina Galinha, Susana Coentro, Célia Alves and Susana Marta Almeida    
This study evaluated the emissions of specific indoor sources usually present in Portuguese dwellings in order to understand their impact on the indoor air quality. With this aim, three typical activities were studied including home heating using two typ... ver más
Revista: Atmosphere

 
Wen-Tien Tsai    
The objective of this paper was to offer a comparative analysis of currently implemented statutory and technical regulations in Taiwan and Japan for volatile organic compounds (VOC) in indoor atmospheres. The findings should help to manage indoor air qua... ver más
Revista: Atmosphere