António Carlos Pinheiro Fernandes, Luís Filipe Sanches Fernandes, Daniela Patrícia Salgado Terêncio, Rui Manuel Vitor Cortes and Fernando António Leal Pacheco
Interactions between pollution sources, water contamination, and ecological integrity are complex phenomena and hard to access. To comprehend this subject of study, it is crucial to use advanced statistical tools, which can unveil cause-effect relationsh...
ver más
|
|
|
|
|
|
|
W. Charles Kerfoot, Gary Swain, Luis M. Verissimo, Erin Johnston, Carol A. MacLennan, Daniel Schneider and Noel R. Urban
Over a century ago, copper mills on the Keweenaw Peninsula of Lake Superior sluiced 64 million metric tonnes (MMT) of tailings into coastal waters, creating a metal-rich ?halo?. Here we show that relatively small discharges can spread widely in time and ...
ver más
|
|
|
|
|
|
|
Henri Pörhö, Jani Tomperi, Aki Sorsa, Esko Juuso, Jari Ruuska and Mika Ruusunen
The aim of wastewater treatment plants (WWTPs) is to clean wastewater before it is discharged into the environment. Real-time monitoring and control will become more essential as the regulations for effluent discharges are likely to become stricter in th...
ver más
|
|
|
|
|
|
|
Jayanga T. Samarasinghe, Randika K. Makumbura, Charuni Wickramarachchi, Jeewanthi Sirisena, Miyuru B. Gunathilake, Nitin Muttil, Fang Yenn Teo and Upaka Rathnayake
Understanding the changes in climate and land use/land cover (LULC) over time is important for developing policies for minimizing the socio-economic impacts of riverine floods. The present study evaluates the influence of hydro-climatic factors and anthr...
ver más
|
|
|
|
|
|
|
Kamalaselvan Arunachalam, Balasubramanian Madanmohan, Rajesh Rajamani, Natarajan Prabaharan, Hassan Haes Alhelou and Pierluigi Siano
The Frequency Response Analysis approach (FRA) is useful in the fault diagnosis of transformers. However, its usefulness in diagnosing any potential sources of Partial Discharge (PD) in transformers has not been thoroughly investigated so far. In this wo...
ver más
|
|
|
|
|
|
|
Daria Wotzka
The results obtained for the measurements of acoustic emission (AE) signal parameters emitted in three dielectric liquids are presented in this paper. In particular, the velocity of AE wave was calculated based on the time of arrival of the AE signal. A ...
ver más
|
|
|
|
|
|
|
Abdullahi Abubakar Mas?ud, Jorge Alfredo Ardila-Rey, Ricardo Albarracín, Firdaus Muhammad-Sukki and Nurul Aini Bani
This paper compared the capabilities of the artificial neural network (ANN) and the fuzzy logic (FL) approaches for recognizing and discriminating partial discharge (PD) fault classes. The training and testing parameters for the ANN and FL comprise stati...
ver más
|
|
|
|
|
|
|
Wojciech Sikorski, Krzysztof Walczak and Piotr Przybylek
Most power transformers operating in a power system possess oil-paper insulation. A serious defect of this type of insulation, which is associated with long operation time, is an increase in the moisture content. Moisture introduces a number of threats t...
ver más
|
|
|
|
|
|
|
Santiago Alfredo Dorrbercker Drake,Ivón Oristela Benítez González,William José Torres Medina,Alejandro Urquiola Lescaille
Pág. 202 a la 2
La medición de descargas parciales (DP) se sustenta en la detección y filtraje de pulsos de corriente que aparecen en una banda de frecuencia que abarca desde los kilohertzios hasta los gigahertzios, por tal motivo los detectores de descargas parciales (...
ver más
|
|
|
|
|
|
|
Weigen Chen, Xi Chen, Shangyi Peng and Jian Li
Dissolved gas analysis (DGA) has been widely applied to diagnose internal faults in transformer insulation systems. However, the accuracy of DGA technique is limited because of the lack of positive correlation of the fault-identifying gases with faults f...
ver más
|
|
|
|