Irene Fernández García, Daniele Novara and Aonghus Mc Nabola
Pressure Reducing Valves (PRV) have been widely used as a device to control pressure at nodes in water distribution networks and thus reduce leakages. However, an energy dissipation takes place during PRV operation. Thus, micro-hydropower turbines and, m...
ver más
|
|
|
|
|
|
|
Xiaojun Zhu, Longji Dang, Shuting Liang, Ming Zhang, Jian Yang and Xin Dai
To investigate the hysteretic behavior of an X-shaped metal damper (XMD) with an oblique angle, cyclic loading tests were carried out on nine specimens, including two XMDs without buckling-restrained devices, four XMDs with stiffening ribs, and three XMD...
ver más
|
|
|
|
|
|
|
Yeshou Xu, Qi He, Ying-Qing Guo, Xing-Huai Huang, Yao-Rong Dong, Zhong-Wei Hu and Jinkoo Kim
Viscoelastic dampers are conventional passive vibration control devices with excellent energy dissipation performance. The fractional derivative has a simple form and high accuracy in the modelling of viscoelastic materials/dampers. The internal variable...
ver más
|
|
|
|
|
|
|
Chengze Wang, Huawei Lu, Xiaozhi Kong, Shiqi Wang, Dongzhi Ren and Tianshuo Huang
The high curvature of modern S-ducts causes a strong secondary flow, which seriously affects the uniformity of the compressor inlet flow. In this study, the flow control method of a pulsed jet was applied in the S-duct at an incoming Mach number of 0.4. ...
ver más
|
|
|
|
|
|
|
Jiang Wang, Kai Hu, Kechen Tang, Yubing Xing, Yani Xiao, Yutian Liu, Yonggao Yan and Dongwang Yang
Air conditioning has become a necessity in people?s daily life. The performance of the compressor determines the energy efficiency ratio of this electrical equipment, but the heat generated during the operation of its internal core power components will ...
ver más
|
|
|
|
|
|
|
Chengquan Wang, Zheng Qu, Yun Zou, Chongli Yin, Yanwei Zong and Zexuan Sun
In order to develop a new type of prefabricated bridge structure system with green, efficient and recoverable function, which complies with the new requirements of rapid repair of pier function after earthquake, and improves the applicable performance of...
ver más
|
|
|
|
|
|
|
Santiago Mota-Páez, David Escolano-Margarit and Amadeo Benavent-Climent
This work can be applied to the seismic upgrading of existing reinforced concrete structures with a soft story located near a fault by using metallic-type displacement-dependent dampers.
|
|
|
|
|
|
|
S. Tangwe, K. Kusakana
Air source heat pump (ASHP) water heaters are efficient devices for sanitary hot water heating. The coefficient of performance (COP) of the air to water heat pump (AWHP) is constantly lower than that of the corresponding ASHP unit. The study focused on d...
ver más
|
|
|
|
|
|
|
Rita Claudia Iotti and Fausto Rossi
To simplify the design and optimization of new-generation nanomaterials and related electronic and optoelectronic quantum devices, energy dissipation versus decoherence phenomena are often simulated via local models based on the Wigner-function formalism...
ver más
|
|
|
|
|
|
|
Irina Boshkova,Oleksandr Titlov,Natalya Volgusheva,Catherina Georgiesh,Tetiana Sahala
Pág. 47 - 54
This paper reports a study of the thermoacoustic phenomena in steam-generating channels of the cooling system of heat-loaded devices. The examined cooling modes are characterized by surface boiling of the heat carrier, which occurs due to high heat flows...
ver más
|
|
|
|