Gang Zhao, Tian Qiu and Peng Liu
Rotor-stator cavities are often found in turbomachinery; they supply cold air that is bled from the compressor to the turbine blades. The pressure of the outlet of a rotor-stator cavity is axisymmetric under normal circumstances. However, its pressure wo...
ver más
|
|
|
|
|
|
|
Gang Zhao, Tian Qiu and Peng Liu
The pre-swirl stator-rotor system is a common and important structure in gas turbines, and its main function is to provide cold air to the turbine blades with a low relative total temperature. Under normal conditions, the boundaries of the system are sym...
ver más
|
|
|
|
|
|
|
Yunjung Jang, Hakgeun Kim and Kiweon Kang
Composite wind turbine blades may experience interlaminar damage, including adhesive failure, cracking, and interlaminar fracture failure, from manufacturing or external fatigue load. Among these, the adhesive failure of adhesive joints is critical. Ther...
ver más
|
|
|
|
|
|
|
Mongkol Kaewbumrung, Worapol Tangsopa and Jatuporn Thongsri
A gas turbine power plant in Thailand had the problem of compressor blade fracture in Stages 6?8, which was caused by housing damage. This gas turbine has a total of 15 stages. The housing damage reduced the lifetime of blades to an unacceptable level. T...
ver más
|
|
|
|
|
|
|
Mihai Florian and John Dalsgaard Sørensen
Out of the total wind turbine failure events, blade damage accounts for a substantial part, with some studies estimating it at around 23%. Current operation and maintenance (O&M) practices typically make use of corrective type maintenance as the basi...
ver más
|
|
|
|