Georgia E. Thermou and Sousana Tastani
This paper investigates experimentally the structural performance of substandard reinforced concrete (RC) short columns confined with steel-reinforced grout (SRG) jackets under monotonically increasing uniaxial compression. The study comprised 24 square ...
ver más
|
|
|
|
|
|
|
Udhayasuriyan Brindha, Jeyaprakash Maheswaran, Maheswaran Chellapandian and Nakarajan Arunachelam
Maintenance of reinforced concrete (RC) structures has become a global issue due to the problems associated with the corrosion of steel reinforcement. Corrosion of RC structures results in severe serviceability and strength issues, which in turn necessit...
ver más
|
|
|
|
|
|
|
Min-Su Jo, Hyeong-Gook Kim, Dong-Hwan Kim, Jin-Hyeong Choi and Kil-Hee Kim
There has recently been growing interest in making a sustainable and durable fiber reinforced cementitious matrix (FRCM) to improve the seismic performance of RC column members. However, most studies evaluating the lateral confinement effect on FRCM jack...
ver más
|
|
|
|
|
|
|
Sousana Tastani and Georgia Thermou
This paper presents a rapid seismic assessment and Fibre Reinforced Polymer (FRP) retrofit design methodology which relies on the European design guidelines recently published in Chapter 8 of fib Bulletin 90 on the use of externally applied FRP reinforce...
ver más
|
|
|
|
|
|
|
Idris Bedirhanoglu
One of the reasons that cause the collapse of buildings is deficient short columns, which need to be retrofitted to prevent the collapse of the building in a potential earthquake. External reinforced concrete (RC), steel plates, and fiber-reinforced poly...
ver más
|
|
|
|
|
|
|
Senad Medic and Mustafa Hrasnica
Low-rise residential and public masonry structures constitute a large portion of the building patrimony, yet they were erected during the massive reconstruction of Southeast Europe after World War II before any design rules existed in the engineering pra...
ver más
|
|
|
|
|
|
|
Naci Caglar,Halil Sezen,Muhammed Nadir Olabi
Pág. 301 - 310
Reinforced concrete jacketing is one of the most frequently used methods for strengthening of reinforced concrete (RC) columns. A large number of experimental studies have been carried out to investigate the effectiveness of repair and strengthenin...
ver más
|
|
|
|
|
|
|
Davide Lavorato, Camillo Nuti and Silvia Santini
In recent years, old reinforced concrete (RC) buildings have increasingly been protected as historic symbols in Italy. The conversion of these buildings can resolve the increasing need for new structures, reducing much social, economic, and environmental...
ver más
|
|
|
|
|
|
|
Xiao, Y; Wu, H; Martin, G R
Pág. 255 - 264
|
|
|
|
|
|
|
Xiao, Yan; Ma, Rui
Pág. 1357 - 1364
|
|
|
|