Inicio  /  Energies  /  Vol: 9 Núm: 3 Par: March (2016)  /  Artículo
ARTÍCULO
TITULO

Application of Breathing Architectural Members to the Natural Ventilation of a Passive Solar House

Kyung-Soon Park    
Sang-Woo Kim and Seong-Hwan Yoon    

Resumen

The efficient operation of a passive solar house requires an efficient ventilation system to prevent the loss of energy and provide the required ventilation rates. This paper proposes the use of ?breathing architectural members? (BAMs) as passive natural ventilation devices to achieve much improved ventilation and insulation performance compared to mechanical ventilation. Considering the importance of evaluating the ventilation and insulation performances of the members, we also propose numerical models for predicting the heat and air movements afforded by the members. The numerical model was validated by comparison with experimental results. The effectiveness of the BAMs was also verified by installation in houses located in an area with warm climate. For this purpose, chamber experiments were performed using samples of the BAMs, as well as numerical simulations to assess natural ventilation and heat load. The main findings of the study are as follows: (1) the one-dimensional chamber experiments confirmed the validity of the numerical models for predicting the heat and air movements afforded by the BAMs. Comparison of the experimental and calculated values for the temperature of air that flowed into the room from outside revealed a difference of less than 5%; (2) observations of the case studies in which BAMs were installed in the ceilings and exterior walls of Tokyo model houses revealed good annual ventilation and energy-saving effects. When BAMs with an opening area per unit area of A = 0.002 m2/m2 were applied to three surfaces, the required ventilation rate was 0.5 ACH (air changes per hour), and this was achieved consistently. Compared to a house with general insulation and conventional mechanical ventilation, heating load was reduced by 15.3%?40.2% depending on the BAM installation points and the differing areas of the house models.

 Artículos similares

       
 
Xiaozhou Wu, Hao Gao, Mingming Zhao, Jie Gao, Zhen Tian and Xiangli Li    
A ceiling cooling system integrated with a mechanical ventilation system has been widely used in modern buildings with large sensible cooling loads due to the high thermal comfort level and large energy efficiency. However, there is a lack of systematic ... ver más
Revista: Buildings

 
Xudong Xie, Qianqian Yang, Weijun Gao and Shudi Wang    
In winter, many rural people in the coastal areas of northern China burn coal for both cooking and heating. As a result, the rural population is seriously affected by indoor air pollution. To analyze the influence of the location of heating sources on th... ver más
Revista: Buildings

 
Karim Touati, Mohammed-Hichem Benzaama, Yassine El Mendili, Malo Le Guern, François Streiff and Steve Goodhew    
Knowledge of indoor air quality (IAQ) in cob buildings during the first few months following their delivery is of vital importance in preventing occupants? health problems. The present research focuses on evaluating IAQ in cob buildings through a prototy... ver más
Revista: Buildings

 
Si Gao, Hu Xie, Mian Yang, Qiang Zhang, Ming Zhang, Xin Wang and Ze-Hao Jiang    
The outbreak of COVID-19 has engendered extensive challenges for conventional hospital operations. To adapt to this problematic issue, a mixed-use hospital functioning system for normal and epidemic situations is proposed. However, the inherent complexit... ver más
Revista: Buildings

 
Yuchen Ju, Pauli Hiltunen, Juha Jokisalo, Risto Kosonen and Sanna Syri    
Demand response techniques can be effective at reducing heating costs for building owners. However, few studies have considered the dynamic marginal costs for district heating production and taken advantage of them for building-level demand response. In ... ver más
Revista: Buildings