Inicio  /  Applied Sciences  /  Vol: 10 Par: 21 (2020)  /  Artículo
ARTÍCULO
TITULO

Sensitivity and Calibration of the FT-IR Spectroscopy on Concentration of Heavy Metal Ions in River and Borehole Water Sources

Matthew Mamera    
Johan J. van Tol    
Makhosazana P. Aghoghovwia and Elmarie Kotze    

Resumen

Heavy metals in water sources can threaten human life and the environment. The analysis time, need for chemical reagents, and sample amount per analysis assist in monitoring contaminants. Application of the Fourier Transform Infrared (FT-IR) Spectroscopy for the investigation of heavy metal elements has significantly developed due to its cost effectiveness and accuracy. Use of chemometric models such as Partial Least Square (PLS) and Principle Component Regression Analysis (PCA) relate the multiple spectral intensities from numerous calibration samples to the recognized analytes. This study focused on the FT-IR calibration and quantification of heavy metals (Ag, Cd, Cu, Pb and Zn) in surveyed water sources. FT-IR measurements were compared with the atomic absorption spectrometer (AAS) measurements. Quantitative analysis methods, PCA and PLS, were used in the FT-IR calibration. The spectral analyses were done using the Attenuated Total Reflectance (ATR-FTIR) technique on three river and four borehole water sources sampled within two seasons in QwaQwa, South Africa (SA). The PLS models had good R2 values ranging from 0.95 to 1 and the PCA models ranged from 0.98 to 0.99. Significant differences were seen at 0.001 and 0.05 levels between the PLS and PCA models for detecting Cd and Pb in the water samples. The PCA models detected Ag concentrations more (?0 mg L-1 on selected sites). Both the PLS and PCA models had lower detection only for Zn ions mostly above 45 mg L-1 deviating from the AAS measurements (<0.020 mg L-1). The FT-IR spectroscopy demonstrated good potential for heavy metal determination purposes.

 Artículos similares

       
 
David Dunkerley    
The inter-tip times (ITTs) of tipping-bucket rain gauges (TBRGs) potentially provide the highest-resolution intensity data that can be acquired from this type of gauge. At an intensity of 100 mm h-1, a typical gauge with a sensitivity of 0.2 mm of rainfa... ver más
Revista: Water

 
Enzhan Zhang, Liang Li, Weiche Huang, Yucheng Jia, Minghu Zhang, Faming Kang and Hu Da    
Large-scale particle image velocimetry (LSPIV) is a computer vision-based technique renowned for its precise and efficient measurement of river surface velocity. However, a crucial prerequisite for utilizing LSPIV involves camera calibration. Conventiona... ver más
Revista: Water

 
Jeonghoon Lee, Jeonghyeon Choi, Jiyu Seo, Jeongeun Won and Sangdan Kim    
In the context of hydrological model calibration, observational data play a central role in refining and evaluating model performance and uncertainty. Among the critical factors, the length of the data records and the associated climatic conditions are p... ver más
Revista: Water

 
Ming Chen, Kai Huang, Jian Wang, Wenzhi Liu and Yuanyuan Shi    
The reliability of urban transportation systems is crucial for ensuring smooth traffic flow and minimizing disruptions caused by external factors. This study focuses on improving the stability and efficiency of transportation systems through the calibrat... ver más
Revista: Applied Sciences

 
Anatoly Kalyakin, Alexander Volkov and Liliya Dunyushkina    
An amperometric sensor based on CaZr0.95Sc0.05O3-d (CZS) proton-conducting oxide for the measurement of hydrogen concentration in air was designed and tested. Dense CZS ceramics were fabricated through uniaxial pressing the powder synthesized by the soli... ver más
Revista: ChemEngineering