Inicio  /  Applied Sciences  /  Vol: 10 Par: 2 (2020)  /  Artículo
ARTÍCULO
TITULO

Research on Heat Transfer Performance of Micro-Channel Backplane Heat Pipe Air Conditioning System in Data Center

Liping Zeng    
Xing Liu    
Quan Zhang    
Jun Yi    
Xianglong Liu and Huan Su    

Resumen

This paper deals with the heat transfer performance of a micro-channel backplane heat pipe air conditioning system. The optimal range of the filling rate of a micro-channel backplane heat pipe air conditioning system was determined in the range of 65?75%, almost free from the interference of working conditions. Then, the influence of temperature and air volume flow rate on the heat exchange system were studied. The system maximum heat exchange is 7000?8000 W, and the temperature difference between the inlet and outlet of the evaporator and the condenser is almost 0 °C. Under the optimum refrigerant filling rate, the heat transfer of the micro-channel heat pipe backplane system is approximately linear with the temperature difference between the inlet air temperature of the evaporator and the cooling distribution unit (CDU) inlet water temperature in the range of 18?28 °C. The last part compares the heat transfer characteristics of two refrigerants at different filling rates. The heat transfer, pressure, and refrigerant temperature of R134a and R22 are the same with the change of filling rate, but the heat transfer of R134a is lower than that of R22. The results are of great significance for the operational control and practical application of a backplane heat pipe system.

 Artículos similares

       
 
Ping Liu, Wentao Shi, Bo Sun, Qian Wang, Xiaokun Xie and Changqing Li    
Burial stone relics remain in a humid, semi-enclosed environment for long periods, and temperature and humidity variations can cause deterioration acceleration. Yang Can?s tomb was selected as the research object, and field monitoring and simulations wer... ver más
Revista: Applied Sciences

 
Yaoyu Yan, Futang Xing, Haonan Gao and Dan Mei    
The cable room, located at the base of the ring main unit, is prone to water vapor due to its proximity to damp cable holes and its relatively enclosed structure. This may penetrate internally and ultimately affect operational safety. Therefore, a dehumi... ver más
Revista: Applied Sciences

 
Jiahao Chen, Jiaxin Li, Deqian Zheng, Qianru Zheng, Jiayi Zhang, Meimei Wu and Chaosai Liu    
The multi-field coupling of grain piles in grain silos is a focal point of research in the field of grain storage. The porosity of grain piles is a critical parameter that affects the heat and moisture transfer in grain piles. To investigate the distribu... ver más
Revista: Applied Sciences

 
Martynas Drazdauskas and Sergejus Lebedevas    
The capability of operational marine diesel engines to adapt to renewable and low-carbon fuels is considered one of the most influential methods for decarbonizing maritime transport. In the medium and long term, ammonia is positively valued among renewab... ver más

 
Ahmed Abouelsaad, Greg White and Ali Jamshidi    
Asphalt mixtures age during service in the field, primarily as the result of chemical changes in the bituminous binder phase. The ageing phenomenon changes the properties of the asphalt mixture, including the stiffness modulus, the resistance to deformat... ver más
Revista: Infrastructures