Resumen
Compared to alternating current (AC) grids, direct current (DC) grids are becoming more and more popular. A power distribution approach is suggested in order to solve the issue of uneven power distribution of distributed generation (DG) in a ship DC microgrid. Power control is carried out using a tracking differentiator (TD), while the output power change rate is not greater than the maximum power ramp rate permitted by the battery, and state-of-charge balance is attained quickly. The proposed strategy also reduces the communication pressure on the power grid. A distributed hierarchical control model of a DC microgrid based on a consensus algorithm is created in order to validate the suggested methodology. The simulation results demonstrate that the established model is capable of simulating the DC microgrid accurately, that the states of charge values of the five batteries gradually converge under the adjustment of the secondary strategy, and that the suggested strategy is reasonable and efficient.