Inicio  /  Water  /  Vol: 10 Par: 1 (2018)  /  Artículo
ARTÍCULO
TITULO

Accuracy Evaluation of Two High-Resolution Satellite-Based Rainfall Products: TRMM 3B42V7 and CMORPH in Shanghai

Qin Jiang    
Weiyue Li    
Jiahong Wen    
Can Qiu    
Weiwei Sun    
Qilin Fang    
Ming Xu and Jianguo Tan    

Resumen

Satellite-based rainfall products have extensive applications in global change studies, but they are known to contain deviations that require comprehensive verification at different scales. In this paper, we evaluated the accuracies of two high-resolution satellite-based rainfall products: the Tropical Rainfall Measurement Mission (TRMM) rainfall product 3B42V7 and the Climate Prediction Center morphing (CMORPH) technique from January 2010 to December 2011 in Shanghai, by using categorical metrics (Probability of Detection, False Alarm Ratio, and Critical Success Index) and statistical indicators (Mean Absolute Error, Root Mean Square Error, Relative Bias, and Correlation Coefficient). Our findings show that, firstly, CMORPH data has a higher accuracy than 3B42V7 at the daily scale, but it underestimates the occurrence frequency of daily rainfall for some intensity ranges. Most errors of the two products are distributed between -10 and 10 mm/day. Second, at the monthly scale, the total accuracy of 3B42V7 is higher than CMORPH in terms of the value of the Correlation Coefficient (CC) and Relative Bias (RB). Finally, CMORPH brings about daily rainfall detection results from categorical metrics computation better than 3B42V7. Generally, the two satellite-based rainfall products show a high correlation with rain gauge data in Shanghai, particularly in spring and winter. Unfortunately, in summer, both of them do not perform well in detecting the short-duration heavy rainfall events. Overall, the relatively poor data accuracy has limited their further applications in Shanghai and similar urban areas.

 Artículos similares

       
 
J. D. Tamayo-Quintero, J. B. Gómez-Mendoza and S. V. Guevara-Pérez    
Objective: This study aims to introduce and assess a novel AI-driven tool developed for the classification of orthodontic arch shapes into square, ovoid, and tapered categories. Methods: Between 2016 and 2019, we collected 450 digital dental models. Appl... ver más
Revista: Applied Sciences

 
Fengwei Jing, Fenghe Li, Yong Song, Jie Li, Zhanbiao Feng and Jin Guo    
The concept of production stability in hot strip rolling encapsulates the ability of a production line to consistently maintain its output levels and uphold the quality of its products, thus embodying the steady and uninterrupted nature of the production... ver más
Revista: Algorithms

 
Matteo Bozzano, Domenico Sguerso, Paolo Zatelli, Davide Zendri and Angelo Besana    
The availability of digital copies of historical artifacts modeling the territory through the so-called ?plan-reliefs? is important for many reasons: the preservation of the artifact if the physical object is damaged or destroyed, the possibility of crea... ver más

 
Palone Mario, Silvia Squeo de Villagomez, Pellitteri Federica, Francesca Cremonini, Renato Salvatore and Luca Lombardo    
Background: To investigate the accuracy of an F22 Aligner system, considering the amount of prescribed movement, tooth type, grip points, sex and age. Methods: Digital models of 120 patients (64 females and 56 males; mean age 35.2 years ± 7.4) affected b... ver más
Revista: Applied Sciences

 
Alexandra P. Schneider, Benoit Paoletti, Xavier Ottavy and Christoph Brandstetter    
Experimental monitoring of blade vibration in turbomachinery is typically based on blade-mounted strain gauges. Their signals are used to derive vibration amplitudes which are compared to modal scope limits, including a safety factor. According to indust... ver más