Inicio  /  Applied Sciences  /  Vol: 14 Par: 6 (2024)  /  Artículo
ARTÍCULO
TITULO

Assessing Jump Performance: Intra- and Interday Reliability and Minimum Difference of Countermovement Jump and Drop Jump Outcomes, Kinetics, Kinematics, and Jump Strategy

Jaime González-García    
Manuel Conejero and Jorge Gutiérrez-Hellín    

Resumen

Understanding the reliability of jump testing is essential to determine the neuromuscular progress of athletes and make informed decisions. This study aimed to assess the reliability of several countermovement jump (CMJ) and drop jump (DJ) test metrics in female volleyball players. Sixteen (n = 16) semi-professional female volleyball players participated in this test-retest study. Intrasession and intersession reliability of CMJ and DJ metrics were evaluated using a randomized cross-over design. A dual force platform was used to collect CMJ and DJ data, and several dependent variables were calculated using forward dynamics. Intraclass correlation coefficients (ICC), coefficients of variation (CV), and minimum difference (MD) were calculated to assess intra- and interday reliability. During the same testing, the third attempt consistently yielded the highest values for both tests in jump height but presented excellent reliability (CMJ: ICC [95%CI] = 0.97 [0.93?0.99]; CV [95%CI] = 4.1% [1.2?7.0]; MD95 = 3.5 cm; MD90 = 2.9 cm; DJ: ICC [95%CI] = 0.91 [0.77?0.97]; CV [95%CI] = 6.7% [1.9?11.5]; MD95 = 6.0 cm; MD90 = 5.0 cm). CMJ height exhibited excellent reliability between sessions (ICC [95%CI] = 0.93 [0.81?0.97]; CV [95%CI] = 3.8% [1.1?6.4]; MD95 = 3.5 cm; MD90 = 3.0 cm), whereas DJ height demonstrated slightly lower but still acceptable intersession reliability (ICC [95%CI] = 0.81 [0.55?0.93]; CV [95%CI] = 6.1% [1.7?10.4]; MD95 = 5.2 cm; MD90 = 4.4 cm). Intersession reliability for CMJ kinetics and kinematics was excellent for 13 of the 24 metrics assessed. For DJ, only concentric (ICC [95%CI] = 0.91 [0.76?0.97]; CV [95%CI] = 3.0% [0.9?5.2]; MD95 = 15 Ns; MD90 = 12.6 Ns) and eccentric impulses (ICC [95%CI] = 0.99 [0.96?0.99]; CV [95%CI] = 1.7% [0.5?2.9]; MD95 = 9.2 Ns; MD90 = 7.7 Ns) demonstrated excellent intersession reliability. Most CMJ variables showed excellent reliability within sessions, while DJ had lower reliability in most metrics. These findings provide valuable information to physical trainers to select the metrics to assess athletes? performance as well as to identify a minimum cut-off value that serves as a reference for each of the metrics reported in both tests.

Palabras claves

 Artículos similares

       
 
Xuyi Zhang, Yang Bai, Yuan Ma, Peidong He, Yinhui Tang and Xiaoning Lv    
Raman spectroscopy has been widely applied in numerous fields including bioanalysis, disease diagnosis, and molecular recognition, owing to its unique advantages of being non-invasive, rapid, and highly specific. However, the acquisition of Raman spectra... ver más
Revista: Applied Sciences

 
Nasser Lotfi and Mazyar Ghadiri Nejad    
Multi-objective task graph scheduling is a well-known NP-hard problem that plays a significant role in heterogeneous distributed systems. The solution to the problem is expected to optimize all scheduling objectives. Pretty large state-of-the-art algorit... ver más
Revista: Applied Sciences

 
Abdullah Ali Jawad Al-Abadi, Mbarka Belhaj Mohamed and Ahmed Fakhfakh    
In recent years, the combination of wireless body sensor networks (WBSNs) and the Internet ofc Medical Things (IoMT) marked a transformative era in healthcare technology. This combination allowed for the smooth communication between medical devices that ... ver más
Revista: Computers

 
Vivek Kumar Prasad, Debabrata Dansana, Madhuri D. Bhavsar, Biswaranjan Acharya, Vassilis C. Gerogiannis and Andreas Kanavos    
With the proliferation of IoT devices, there has been exponential growth in data generation, placing substantial demands on both cloud computing (CC) and internet infrastructure. CC, renowned for its scalability and virtual resource provisioning, is of p... ver más
Revista: Information

 
Dionysios N. Markatos, Sonia Malefaki and Spiros G. Pantelakis    
When it comes to achieving sustainability and circular economy objectives, multi-criteria decision-making (MCDM) tools can be of aid in supporting decision-makers to reach a satisfying solution, especially when conflicting criteria are present. In a prev... ver más
Revista: Aerospace