Perceived Thermal Discomfort and Stress Behaviours Affecting Students? Learning in Lecture Theatres in the Humid Tropics

Tamaraukuro Tammy Amasuomo and Japo Oweikeye Amasuomo    

Resumen

The study investigated the relationship between students? perceived thermal discomfort and stress behaviours affecting their learning in lecture theatres in the humid tropics. Two lecture theatres, LTH-2 and 3, at the Niger Delta University, Nigeria, were used for the study. Two groups of students from the Faculties of Agriculture and Engineering and the Department of Technology Education constituted the population. The sample size selected through random sampling for Groups A and B was 210 and 370 students, respectively. Objective and self-report instruments were used for data collection. The objective instrument involved physical measurement of the two lecture theatres and of the indoor temperature, relative humidity and air movement. The self-report instrument was a questionnaire that asked for the students perceived indoor thermal discomfort levels and the effect of indoor thermal comfort level on perceived stress behaviours affecting their learning. The objective indoor environmental data indicated thermal discomfort with an average temperature of 29?32 °C and relative humidity of 78% exceeding the ASHARE [1] and Olgyay [2].The students? experienced a considerable level of thermal discomfort and also perceived that stress behaviours due to thermal discomfort affected their learning. Further, there were no significant differences in the perceived thermal discomfort levels of the two groups of students in LTH-2 and 3. Furthermore, stress behaviours affecting learning as perceived by the two groups of students did not differ significantly. In addition, no correlation existed between the perceived indoor thermal discomfort levels and stress behaviour levels affecting learning for students in LTH-2, because the arousal level of the students in the thermal environment was likely higher than the arousal level for optimal performance [3,4]. However, a correlation existed in the case of students in LTH-3, which was expected because it only confirmed the widely-accepted view that stress behaviours exhibited by students in any learning can have a profound effect on learning. It was recommended that teaching-learning indoor environment should be thermally comfortable by providing adequate window openings with proper orientation and also by ensuring that the learning space only accommodated the required student capacity to reduce the stress behaviours that affect learning.

 Artículos similares

       
 
Paolo Valdiserri, Silvia Cesari, Maddalena Coccagna, Pasquale Romio and Sante Mazzacane    
Hospitals require the highest energy demands in non-residential buildings. They provide healthcare 24/7/365 and, at the same time, they ensure indoor air quality, thermal comfort and sterility. However, several studies reveal that high indoor temperature... ver más
Revista: Buildings

 
Aiman Albatayneh, Dariusz Alterman, Adrian Page and Behdad Moghtaderi    
To design energy-efficient buildings, energy assessment programs need to be developed for determining the inside air temperature, so that thermal comfort of the occupant can be sustained. The internal temperatures could be calculated through computationa... ver más
Revista: Buildings

 
Hyungkeun Kim, Kyungsoo Lee and Taeyeon Kim    
Two types of methods are used to evaluate pedestrian comfort: pedestrian wind comfort and outdoor thermal comfort. To accurately ascertain the outdoor wind environment, wind speed is the only parameter considered. However, pedestrians may still feel disc... ver más
Revista: Sustainability

 
Jihyun Park, Vivian Loftness and Azizan Aziz    
The indoor environmental quality (IEQ) of buildings can have a strong influence on occupants’ comfort, productivity, and health. Post-occupancy evaluation (POE) is necessary in assessing the IEQ of the built environment, and it typically relies on ... ver más

 
John Dadzie, Goran Runeson, Grace Ding and Francis K. Bondinuba    
Globally, only 2% of existing building stock is built yearly; the remaining 98% already exist. Energy consumption and indoor thermal comfort of the existing building stock are not encouraging. This is due to many challenges associated with existing build... ver más