Redirigiendo al acceso original de articulo en 18 segundos...
ARTÍCULO
TITULO

Procedure for calculating the thermoacoustic pressure fluctuations at boiling subcooled liquid

Irina Boshkova    
Oleksandr Titlov    
Natalya Volgusheva    
Catherina Georgiesh    
Tetiana Sahala    

Resumen

This paper reports a study of the thermoacoustic phenomena in steam-generating channels of the cooling system of heat-loaded devices. The examined cooling modes are characterized by surface boiling of the heat carrier, which occurs due to high heat flows at the cooled surface and large underheating of the flow core to the saturation temperature. Under such conditions, high-frequency pulsations of acoustic pressure may occur in cooling channels. It has been established that the emergence of thermoacoustic oscillations could lead to the formation of a standing wave in the channel, one of the conditions for whose formation is the presence of a wave reflection boundary. We have proposed a mathematical model describing the generation of thermoacoustic vibrations in a cooling channel. It was assumed that fluctuations with a high amplitude arise due to the resonance observed when the frequency of forced vibrations of steam bubbles coincides with the vapor-liquid column's natural frequency of vibrations or their harmonics. To calculate the amplitude of pressure fluctuations in the channel, the dependence has been derived, which takes into consideration the viscous dissipation of energy and energy losses at the ends of the channel. It has been shown that when approaching the resonance, the contribution of volumetric viscosity to the viscosity absorption factor increases. It has been established that for the examined conditions the losses of energy on the walls of the channel and losses in the boundary layer could be neglected. We have calculated the amplitude of thermoacoustic pressure fluctuations for conditions corresponding to actual processes in surface-boiling cooling channels. The reported procedure is proposed to be used in the design of liquid cooling systems for heat-loaded devices for which cooling modes imply a significant underheating of the heat carrier to a saturation temperature, as well as surface boiling

 Artículos similares

       
 
Robert Maier     Pág. 75 - 81
The article discusses the problem of automating the procedure for assessing the semantic complexity of "ordinary" words and scientific concepts, which is necessary to determine the educational text complexity. The complexity of the concept P relative to ... ver más

 
Miao Zhang, Peng Jiao, Yong Peng and Quanjun Yin    
Cloud computing has been studied and used extensively in many scenarios for its nearly unlimited resources and X as a service model. To reduce the latency for accessing the remote cloud data centers, small data centers or cloudlets are deployed near end-... ver más
Revista: Applied Sciences

 
Aleksander Grm    
This paper deals with the hydrodynamic effect of the ship on a flexible dolphin during a mooring manoeuvre. The hydrodynamic effect refers to the change in momentum of the surrounding fluid, which is defined by the concept of added mass. The main reason ... ver más

 
Michal Pawlak, Timo Kruck, Nikolai Spitzer, Dariusz Dziczek, Arne Ludwig and Andreas D. Wieck    
In this paper, we validate two theoretical formula used to characterize thermal transport of superlattices at different temperatures. These formulas are used to measure cross-plane thermal conductivity and thermal boundary resistance, when it is not poss... ver más
Revista: Applied Sciences

 
Roy Gafter and Nitai Drimer    
Very large floating structure (VLFS) is a sustainable concept centered around creating solid platforms at sea. The Delta is a new type of VLFS, designed to withstand open-sea conditions and to form, in addition to a broad deck areas, a sheltered basin of... ver más