Redirigiendo al acceso original de articulo en 24 segundos...
ARTÍCULO
TITULO

Fault Detection of Stator Inter-Turn Short-Circuit in PMSM on Stator Current and Vibration Signal

Hong Liang    
Yong Chen    
Siyuan Liang and Chengdong Wang    

Resumen

The stator inter-turn short circuit fault is one of the most common and key faults in permanent magnet synchronous motor (PMSM). This paper introduces a time–frequency method for inter-turn fault detection in stator winding of PMSM using improved wavelet packet transform. Both stator current signal and vibration signal are used for the detection of short circuit faults. Two different experimental data from a three-phase PMSM were processed and analyzed by this time–frequency method in LabVIEW. The feasibility of this approach is shown by the experimental test.