Redirigiendo al acceso original de articulo en 17 segundos...
ARTÍCULO
TITULO

ON THE EXCITATION OF LOCAL ELECTRIC CURRENT IN THE BIOLOGICAL ENVIRONMENT

Igor Bondarenko    
Oleg Avrunin    

Resumen

The subject of the study in the article is to study the method of excitation of human body tissues using an electric current. The purpose of the work is to develop a method for exciting local current in a human body affecting the microcirculation of blood and excitability of local areas of muscle tissue during the treatment process. The article solves the following tasks: the creation of a model pattern of fabric, the rationale for the generation of electric current inside the sample, the development of the design of the current generation system and measuring the electrical response of the model sample of the tissue on the occurrence of electric current, determining the size and spatial current distribution in the model sample of the fabric, comparison The obtained current values with known and admissible in medical practice its values, determination of the advantages of the proposed method of excitation of current compared to the traditional used in medicine. The following methods were used: analysis of scientific publications for the subject of the study, the calculation of the expected current parameters in the model sample, the method of designing the nodes of the current generation and measurement system of the electrical response, the experimental method of excitation of the current and measuring the sample response to it. The following results were obtained: a new acoustic-magnetic method of exciting electric current in local areas of muscle tissue is justified, which allows determining for them the optimal values of the therapeutic current and the value of its threshold value. model samples of muscle tissue are created, a magnetohydrodynamic method of generating electric current inside the patient's body is justified, design of a system for generating current and measuring the electrical response of a model fabric sample to the occurrence of electric current in it; determining the magnitude and spatial distribution of the current in the model fabric sample; comparison of obtained current values with known and permissible values in medical practice and proved their safety for a person. Calculated ratios are obtained, which connect value of excited local current with parameters of ultrasonic radiation, external permanent magnetic field and biological medium. The materials have been found that the current density excited in the local area of the biological medium is independent of the ultrasound frequency and is determined mainly by the intensity of the ultrasound and the constant magnetic field. The advantages of the current excitation method according to the present invention over the conventional galvanic method of passing current through the patient's skin are the ability to generate current in any desired local area of the patient's tissue and its complete safety. Conclusions: The scientific foundations of the new method of excitation of local current inside the human body have been developed and experimentally tested on model samples. Using this method can significantly increase the effectiveness of the treatment process based on the effect of current on blood microcirculation in predetermined areas of muscle tissue and for the first time will allow distinguishing and determining with high accuracy thresholds of their excitability by electric current.

 Artículos similares

       
 
Dongxi Liu, Xiaoying Wang and Yujiao Chen    
In this work, in order to elucidate the three-dimensional (3D) resonant sloshing dynamics of the oil?water interface in an offshore cylindrical wet storage tank, a series of model experiments are conducted in a completely filled cylindrical tank containi... ver más

 
Bochen Duan, Shengping Wang, Changlong Luo and Zhigao Chen    
In recent years, the surge in marine activities has increased the frequency of submarine pipeline failures. Detecting and identifying the buried conditions of submarine pipelines has become critical. Sub-bottom profilers (SBPs) are widely employed for pi... ver más

 
Guang Ma, Ling Cheng, Yu Han and Chengxu He    
The magnetic properties of a 0.10 mm ultra-thin, grain-oriented (UTGO) silicon steel and an Fe-based amorphous (FBA) alloy under sinusoidal excitation were experimentally researched, and the magnetic field strength and iron loss of the two materials unde... ver más
Revista: Applied Sciences

 
Carlo Boursier Niutta, Pierpaolo Padula, Andrea Tridello, Marco Boccaccio, Francesco Acerra and Davide S. Paolino    
This paper deals with an innovative nondestructive technique for composites (local-IET), which is based on the Impulse Excitation Technique (IET) and, in the presence of damage, assesses the degradation of the elastic properties of a local region of the ... ver más
Revista: Applied Sciences

 
Gerard Andonian, Nathan Burger, Nathan Cook, Scott Doran, Tara Hodgetts, Seongyeol Kim, Gwanghui Ha, Wanming Liu, Walter Lynn, Nathan Majernik, John Power, Alexey Pronikov, James Rosenzweig and Eric Wisniewski    
The recently demonstrated concept of the plasma photocathode, whereby a high-brightness bunch is initialized by laser ionization within a plasma wakefield acceleration bubble, is informally referred to as Trojan Horse wakefield acceleration. In a similar... ver más
Revista: Instruments