Resumen
Future electron-positron collider experiments aim at the precise measurement of the Higgs boson, electroweak physics and the top quark. Based on the particle-flow paradigm, a novel highly granular crystal electromagnetic calorimeter (ECAL) is proposed to address major challenges from jet reconstruction and to achieve the optimal EM energy resolution of around 2?3%/E(GeV)" role="presentation" style="position: relative;">%/??(GeV)-------v%/E(GeV)
%
/
E
(
GeV
)
with the homogeneous structure. Extensive R&D efforts have been carried out to evaluate the requirements and potentials of the crystal calorimeter concept from sensitive detection units to a full sub-detector system. The requirements on crystal candidates, photon sensors as well as readout electronics are parameterized and quantified in Geant4 full simulation. Experiments including characterizations of crystals and silicon photomultipliers (SiPMs) are performed to validate and improve the simulation results. The physics performance of the crystal ECAL is been studied with the particle flow algorithm ?ArborPFA? which is also being optimized. Furthermore, a small-scale detector module with a crystal matrix and SiPM arrays is under development for future beam tests to study the performance for EM showers.