Pressure Optimization in Pneumatic Interfaces Using a Single-Bay Seven-Story Infilled Reinforced Concrete Frame: Experimental and Numerical Investigation

Prem Kumar George    
Thirumurugan Varatharajan    
Satyanarayanan Kachabeswara Srinivasan    
Ibrahim Y. Hakeem and Yasin Onuralp Özkiliç    

Resumen

Reinforced concrete infilled frames have been studied over the years along with the infilled openings. To resist the lateral loads that are applied on the frames, stress is transferred from the reinforced concrete (RC) to infill, which leads to brittle collapse. The conventional interface medium, which was considered by researchers and recent studies, was prepared by changing the interface materials between the RC frame and infill panels to different elastic materials. This study focuses on optimizing the interface pressure using a butyl rubber tube, which reduces the stress distribution to the infill panel from the RC frame. A 50% window opening was adopted in this study, which is the optimized size from previous research. The optimization patterns followed linear and nonlinear patterns, such as the same pressures in all stories and varying pressures in all stories. The third story had a 8 PSI pattern and the other stories had a 2 PSI pattern; all stories with 8 PSI patterns achieved the least displacement when compared to other variations. A monotonic static analysis was performed for both the experimental and analytical study. The boundary conditions were pinned, and coupling interfaces were made for the master and slave surfaces. The pressure conditions were applied in various linear and nonlinear patterns to optimize the pressure. A comparative study was performed on the displacement, stiffness, and drift ratio for the critical position of the interface pressure in both the analytical and experimental studies. The difference was approximately 0.53% in the analytical study and 0.37% in the experimental work. The optimization was performed using both an experimental model and an analytical model, which had an error percentage of 0.61%.

 Artículos similares

       
 
Jafar Jafari-Asl, Seyed Arman Hashemi Monfared and Soroush Abolfathi    
This study investigates the optimal and safe operation of pumping stations in water distribution systems (WDSs) with the aim of reducing the environmental footprint of water conveyance processes. We introduced the nonlinear chaotic honey badger algorithm... ver más
Revista: Water

 
Guowei Hua, Shijie Wang, Meng Xiao and Shaohua Hu    
Dam safety is considerably affected by seepage, and uplift pressure is a key indicator of dam seepage. Thus, making accurate predictions of uplift pressure trends can improve dam hazard forecasting. In this study, a convolutional neural network, (CNN)-ga... ver más
Revista: Water

 
Hua Li, Zifeng Yu, Runan Hua, Chenqi Li, Chao Guo, Houlin Liu and Liang Dong    
The biomimetic surface with Space-V grooves can effectively reduce flow resistance and noise. Our investigation was in order to further enhance the drag reduction and noise reduction performance of a marine centrifugal pump with Space-V-groove-shaped bio... ver más
Revista: Water

 
Federico Spizzo, Giovanni Venaruzzo, Matteo Nicolini and Daniele Goi    
Water Distribution Network Partitioning (WDNP), which is the partitioning of the existing Water distribution Network (WDN) into smaller and more homogeneous portions called District Metered Areas (DMAs), is an effective strategy that allows water utiliti... ver más
Revista: Water

 
Shangye Chu, Xu Zeng, Hai Lin and Yuting Zhu    
The performance of catalytic wet oxidation of excess activated sludge derived from pharmaceutical wastewater treatment over a Cu/?-Al2O3 catalyst was investigated. The experiments were performed with a stainless steel autoclave reactor by using the prepa... ver más
Revista: Water