Redirigiendo al acceso original de articulo en 19 segundos...
Inicio  /  Applied Sciences  /  Vol: 13 Par: 24 (2023)  /  Artículo
ARTÍCULO
TITULO

A Proposal for Risk Assessment of Low-Frequency Noise in the Human?Machine?Environment System

Michaela Balá?iková    
Hana Pacaiová and Marianna Toma?ková    

Resumen

Low-frequency noise, the frequency range from approximately 10 Hz to 200 Hz, has been recognized as a special environmental noise problem. The World Health Organization recognizes the special place of low-frequency noise as an environmental problem. Noise can damage hearing, and it affects the whole body. Low-frequency sound is heard by humans, but infrasound is not audible. Low-frequency sound is most often measured based on a weighting function of the frequency. The A-weighted level underestimates the effects of low-frequency noise. For the detrimental effects of low-frequency sound, it would be appropriate to apply measurements using Z-weighting. The aim of this paper was to propose a comprehensive method of acoustic risk assessment (CMARA) that implements the effects of low-frequency values of noise exposure. The proposed methodology has been applied in practice at four workplaces for seven work activities. A risk assessment using the proposed CMARA method for individual activities shows that the noise exposure time may pose a health risk in the occupational and environmental process due to exposure to low-frequency noise at the limit of audibility. A high risk was assessed for activities WA2 (machining) and WA3 (spot welding). This paper highlights the need to measure low-frequency noise using Z-filter weighting.

 Artículos similares

       
 
Hsien-Ming Chou    
Existing caretakers of long-term care are assigned constrainedly and randomly to taking care of older people, which could lead to issues of shortage of manpower and poor human quality, especially the proportion of older people increases year after year t... ver más
Revista: Applied Sciences

 
Chia-Hsuan Lee, Chi-Han Wu, Bernard C. Jiang and Tien-Lung Sun    
The results obtained by medical experts and inertial sensors via clinical tests to determine fall risks are compared. A clinical test is used to perform the whole timed up and go (TUG) test and segment-based TUG (sTUG) tests, considering various cutoff p... ver más
Revista: Applied Sciences

 
Yosef Ashibani, Dylan Kauling and Qusay H. Mahmoud    
There has been a rapid increase in the number of Internet of Things (IoT) devices in the last few years, providing a wide range of services such as camera feeds, light controls, and door locks for remote access. Access to IoT devices, whether within the ... ver más

 
José Luis Ródenas, Salvador García-Ayllón and Antonio Tomás    
In spite of the enhancements related to building construction, many regions still present a major level of seismic risk as a consequence of the high vulnerability of the urban configuration of their cities. An improved method to assess the seismic vulner... ver más
Revista: Applied Sciences

 
Lars Kayser, Christian Nøhr, Pernille Bertelsen, Lars Botin, Sidsel Villumsen, Chris Showell and Paul Turner    
Background: The WHO framework on integrated people-centred health services promotes a focus on the needs of people and their communities to empower them to have a more active role in their own health. It has advocated five strategies including: Engaging ... ver más
Revista: Informatics