Redirigiendo al acceso original de articulo en 15 segundos...
ARTÍCULO
TITULO

Exergy-Based Efficiency Assessment of Fans vs. Isentropic Efficiency

Johannes Brötz    
Christian Schänzle and Peter F. Pelz    

Resumen

The efficiency definition allows us to compare two machines with each other. In general, the efficiency is defined as the ratio of usable power to the required power. This raises the question: what is the usable power? Most engineers discuss efficiency on the basis of the energy balance, i.e., the first law of thermodynamics. In this paper, we derive the exegetic efficiency taking the second law of thermodynamics into account. Exergy analysis takes into account work and heat and is able to model reality very accurately. On this basis, a comparison between the isentropic and exergetic efficiencies is given. A high-pressure radial fan is used as an example, and the differences are discussed. Therefore, measurements of a non-adiabatic fan are evaluated, and the role of the heat flux in the environment is discussed. The investigations show that a relevant difference between the isentropic and exergetic efficiencies becomes apparent in the partial-load range with high-pressure build-up. The thermal energy contained in the flow belongs proportionally to the exergy, i.e., the working capacity of the gas relative to its environment. For a standard such as ISO 5801 ?Fans?Performance testing using standardized airways?, the efficiency must not only be physically correct, it must also be simple and practical. Against this background, the outlook of this paper discusses when and which efficiency definition is appropriate and best suited for a standard.

Palabras claves

 Artículos similares

       
 
This paper presents the optimization of parallel distribution between electricity and heat production for a geothermal plant. The geothermal fluid is split into two streams, one used for an Organic Rankine Cycle (ORC) system, and the other for a District... ver más
Revista: Energies

 
The thermal energy storage (TES) system stores the district heating (DH) water when the heating load is low. Since a TES system stores heat at atmospheric pressure, the DH water temperature of 115 °C has to be lowered to less than 100 °C. Therefo... ver más
Revista: Energies

 
Gianpiero Evola, Vincenzo Costanzo and Luigi Marletta    
The performance of space heating and cooling systems in buildings is usually measured by applying the first law of thermodynamics, which makes it possible to quantify the energy losses of the single components and to measure their energy conversion effic... ver más

 
Nuri Eshoul, Abdulrahman Almutairi, Rasaq Lamidi, Hamad Alhajeri and Abdulrahman Alenezi    
Desalination is the sole proven technique that can provide the necessary fresh water in arid and semi-arid countries in sufficient quantities and meet the modern needs of a growing world population. Multi effect desalination with thermal vapour compressi... ver más
Revista: Water

 
Mohammed Khennich, Mikhail Sorin and Nicolas Galanis    
The evaluation of the thermodynamic performance of the mutual transformation of different kinds of exergy linked to the intensive thermodynamic parameters of the flow inside the ejector of a refrigeration system is undertaken. Two thermodynamic metrics, ... ver más
Revista: Energies