Wind and Seismic Response Control of Dynamically Similar Adjacent Buildings Connected Using Magneto-Rheological Dampers

Akshay Satishkumar Baheti and Vasant Annasaheb Matsagar    

Resumen

Wind and/or earthquake-imposed loadings on two dynamically similar adjacent buildings cause vigorous shaking that can be mitigated using energy dissipating devices. Here, the vibration response control in such adjacent structures interconnected with semi-active magneto-rheological (MR) dampers is studied, which could also be used as a retrofitting measure in existing structures apart from employing them in new constructions. The semi-active nature of the MR damper is modeled using the popular Lyapunov control algorithm owing to its least computational efforts among the other considered control algorithms. The semi-active performance of the MR damper is compared with its two passive states, e.g., passive-off and passive-on, in which voltage applied to the damper is kept constant throughout the occurrence of a hazard, to establish its effectiveness even during the probable electric power failure during the wind or seismic hazards. The performance of the MR damper, in terms of structural response reduction, is compared with other popular energy dissipating devices, such as viscous and friction dampers. Four damper arrangements have been considered to arrive at the most effective configuration for interconnecting the two adjoining structures. Structural responses are recorded in terms of storey displacement, storey acceleration, and storey shear forces. Coupling the two adjacent dynamically similar buildings results in over a 50% reduction in the structural vibration against both wind and earthquake hazards, and this is achieved by not necessarily connecting all the floors of the structures with dampers. The comparative analysis indicates that the semi-active MR damper is more effective for response control than the other passive dampers.

 Artículos similares

       
 
Zhenzhou Sun, Yang Yu, Huakun Wang, Shanshan Huang and Jiefeng Chen    
This study aims at proposing a simulation method for an offshore converter station platform (OCS) under dynamic loading. A user-defined in-house FORTRAN code was developed based on the Vector Form Intrinsic Finite Element (VFIFE) method, and the numerica... ver más

 
Ariya Eini, Lina Zhou and Chun Ni    
Light-frame wood structures are the most common type of construction for residential and low-rise buildings in North America. The 2015 edition of the National Building Code of Canada has increased the height limit for light-frame wood construction from 4... ver más
Revista: Buildings

 
Yanchao Yue, Changxin Li, Kai Jia, Yuhang Zhang and Jingjing Tian    
To optimize the seismic performance of a new type of steel-concrete tower, a 120 m steel-concrete composite tower model with a tuned mass damper (TMD) was constructed in ABAQUS for simulation analysis. Firstly, a time history analysis was conducted to st... ver más
Revista: Buildings

 
Pankaj Bariker and Sreevalsa Kolathayar    
High-rise building safety is generally supported by pile-mat systems. They must be sturdy enough to withstand potential lateral loads brought on by earthquakes, wind, dredging, and machine vibrations, in addition to increased axial loads. An innovative p... ver más
Revista: Infrastructures

 
Alexandros Petropoulos, Vasilios Kapsimalis, Niki Evelpidou, Anna Karkani and Katerina Giannikopoulou    
Myrtos Beach (Cephalonia Island, Ionian Sea, Greece) represents a pocket beach with strong touristic, economic and natural interest. In this research, the morphodynamic behavior of the coastal area (e.g., hydrodynamic and sedimentary state, morphology, o... ver más