Resumen
Electric arc furnace (EAF) steel slag filters were investigated for their efficiency at reducing the concentration of phosphorus (P) from dairy farm wastewater in Vermont. The primary objective for this study was to examine the use of in series design on filters? performance in P removal from dairy farm wastewater at subzero temperatures. Other research objectives were to investigate operational parameters such as the effects of total suspended solids (TSS) daily mass loading rates and of alternating feeding and resting periods on EAF steel slag filters? TSS, dissolved reactive phosphorus (DRP) and total phosphorus (TP) removal efficiencies and filter system life-span. The utilization of in series filter design increased filter DRP removal efficiency by 35%. In series design also allows for alternating feeding and resting periods, which resulted in a 16%, 57% and 74% increase in TSS, DRP and TP removal efficiencies, respectively, by the first filter in series over a single period. Additionally, the system life span was extended 3.25 fold (from 52 to 169 day). Based on this research, we recommend alternate feeding and resting cycles and in series design to be integrated in the design of EAF steel slag filter systems for highly concentrated agricultural effluents in cold climates.