Resumen
The stimulated reservoir volume (SRV) technology extends conventional fracturing technology. Understanding how to effectively and accurately determine modified fracture shape and volume is the key point to evaluating the stimulation effect. Using electromagnetic detection technology can provide a new option for measuring these parameters. By the finite method, the rationality of electromagnetic detection technology to obtain the relevant parameters of reconstruction fracture is testified through forward simulation. This study compared the signals of fractures with different conductivity, volume, and shape collected by electromagnetic detection tool, and the results show that the signals have a specific correspondence with fracture geometric parameters. According to the electromagnetic signal curve of the forward model, the description of propped fractures, including positions and sizes, can be realized.