Redirigiendo al acceso original de articulo en 15 segundos...
Inicio  /  Clean Technologies  /  Vol: 3 Par: 2 (2021)  /  Artículo
ARTÍCULO
TITULO

Comparative Study of a Clean Technology Based on DSF Use in Occupied Buildings for Improving Comfort in Winter

Eusébio Conceição    
João Gomes    
Maria Manuela Lúcio    
Maria Inês Conceição and Hazim Awbi    

Resumen

This paper presents a comparative study of a clean technology based on a DSF (double skin facade) used in winter conditions in the occupied buildings comfort improvement, namely the thermal comfort and air quality. The performance of a solar DSF system, the building?s thermal response, the internal thermal comfort and the internal air quality are evaluated. In this study, a DSF system, an air transport system and a HVAC (heating, ventilating and air conditioning) system based on mixing ventilation are used. The study considers a virtual chamber occupied by eight persons and equipped, in the outside environment, by three DSFs. A new horary pre-programming control methodology is developed and applied when the airflow rate is constant and the number of DSFs to operate is variable, when the airflow rate is variable and the number of DSFs to operate is constant and when the airflow rate is variable and the number of DSFs to operate is variable. This work uses a numerical model that simulates the integral building thermal behavior and an integral human thermal response. The internal air, provided by a mixing ventilating system, is warmed using the DSF system. The air temperature inside the DSF system and the virtual chamber, the thermal comfort level using the PMV index, the internal air quality using the carbon dioxide concentration and the uncomfortable hours are calculated for winter conditions. The results obtained show that the energy produced in the DSF, using solar radiation, guarantees acceptable thermal comfort conditions in the morning and in the afternoon. The indoor air quality obtained at the breathing level is acceptable. It is found that the airflow rate to be used is more decisive than the DSF operating methodology. However, when a solution is chosen that combines a ventilation rate with the number of DSF to operate, both variables throughout the day can obtain simultaneously better results for indoor air quality and thermal comfort according to the standards.

 Artículos similares

       
 
Lei Jiang and Ziyue Zeng    
Since the impoundment of the Three Gorges Project, the downstream hydrology and river dynamics have been modified. The Yichang?Chenglingji Reach (YCR), as a part of the mainstream of the Middle Yangtze River, has consequently been significantly scoured, ... ver más
Revista: Water

 
Cen-Ying Liao, Lin Zhang, Si-Yu Hu, Shuai-Jie Xia and D. M. Li    
Empowering materials with self-healing capabilities is an attractive approach for sustainable development. This strategy involves using different methods to automatically heal microcracks and damages that occur during the service life of materials or str... ver más
Revista: Buildings

 
Xiaoyun Song, Heping Zheng, Lei Xu, Tingting Xu and Qiuyu Li    
An investigation was carried out to study the influence of two types of anti-washout admixtures (AWAs) on the performance of underwater concrete, specifically, workability and washout resistance. The tested AWAs were hydroxypropyl methylcellulose (HPMC) ... ver más
Revista: Buildings

 
Svetlana Pushkar    
Over the past five years, Leadership in Energy and Environmental Design Commercial Interior version 4 (LEED-CI v4)-certified office projects have been intensively studied in the USA and China, but they have not yet been studied in the Mediterranean regio... ver más
Revista: Buildings

 
Ángel Benigno González-Avilés, Carlos Pérez-Carramiñana, Antonio Galiano-Garrigós and María Isabel Pérez-Millán    
Over the last decade there has been a proliferation of glamping architecture. This study analyses the energy performance of geodesic domes for use in tourist glamping compared to more conventional prismatic architectural solutions. The energy analysis of... ver más
Revista: Buildings