Redirigiendo al acceso original de articulo en 20 segundos...
Inicio  /  Applied Sciences  /  Vol: 11 Par: 5 (2021)  /  Artículo
ARTÍCULO
TITULO

Tooth Root Bending Strength of Gears: Dimensional Effect for Small Gears Having a Module below 5 mm

Franco Concli    

Resumen

Downsizing is a more and more widespread trend in many industrial sectors, and, among the others, the automotive industry is pushing the design of its components towards increasingly compact, lightweight, efficient, and reliable solutions. In the past, the drivetrains for automotive were designed and manufactured with gears having modules in the range 3 to 10. In this respect, the main actual European standards for gear design such as ISO 6336:2019 (based on the DIN 3990:1987) are validated in the 3 to 10 mm range only. Moreover, it is well known that, by increasing the gear size, the gear size factor for tooth bending ???? Y X reduces. However, nowadays the advances in terms of materials and design knowledge have made possible the realization of miniaturized gearboxes with gears having normal modules below 3 mm with comparable (or better) reliability. In this scenario, understanding how the size affects (positively) the load-carrying capacity for tooth root bending for small modules below 5 mm is fundamental to maximize the design effectiveness in case of downsizing of the drivetrains. In this paper an experimental study was performed on small gears made of 39NiCrMo3 having a normal module of 2 mm to verify the load-carrying capacity for tooth root bending. Based on the experimental evidences and additional data from literature and past studies by the author, an extended formula for the size factor YX (according to ISO 6336) is proposed.

Palabras claves

 Artículos similares

       
 
Yanming Mu, Xiangying Hou and Xueming He    
Gear vibration becomes unmanageable under extreme conditions, which shortens the time between overhauls of the helicopter reducer and affects the service efficiency of helicopters. For this purpose, an active precontrol strategy for shape and performance... ver más
Revista: Applied Sciences

 
Margarita Yoshpe, Nikita Ruparel, Shmuel Einy, Shilpa Ganatra and Arieh Y. Kaufman    
We assessed the impact of regenerative endodontic procedures (REP) using a platelet-rich fibrin (PRF) scaffold on necrotic immature permanent anterior and posterior teeth based on the following parameters: periapical healing, changes in root development,... ver más
Revista: Applied Sciences

 
Alessio Buonavoglia, Adriana Trotta, Michele Camero, Marco Cordisco, Michela Maria Dimuccio and Marialaura Corrente    
A massive periodontal destruction can affect the root canal (RC) system and potentially expose the pulpo-dentinal complex to opportunistic bacteria. Streptococcus mutans is a major pathogen of human caries and periodontal diseases, and its virulence most... ver más
Revista: Applied Sciences

 
Andreas Vollmer, Michael Vollmer, Gernot Lang, Anton Straub, Alexander Kübler, Sebastian Gubik, Roman C. Brands, Stefan Hartmann and Babak Saravi    
Background: Oro-antral communication (OAC) is a common complication following the extraction of upper molar teeth. The Archer and the Root Sinus (RS) systems can be used to classify impacted teeth in panoramic radiographs. The Archer classes B-D and the ... ver más
Revista: Applied Sciences

 
Franco Concli and Athanasios Kolios    
Wind turbine gearboxes are known to be among the weakest components in the system and the possibility to study and understand the behavior of geared transmissions when subject to several types of faults might be useful to plan maintenance and eventually ... ver más
Revista: Computation