Resumen
The baseflow separation method based on a digital filter is a simple method for separating the baseflow from streamflow. Appropriate estimation of filter parameters is required to use the digital filter method for analysis. We carried out sensitivity analysis on four digital filter methods: Lyne?Hollick (LH), Chapman, Chapman and Maxwell (CM), and exponentially weighted moving average (EWMA). Furthermore, appropriate filter parameters were suggested for each method in this study. By applying them to 25 stage stations in the Nakdong River in the Republic of Korea, the four methods were evaluated. The results of the evaluation showed that the Chapman and CM methods had problems separating the baseflow during the dry seasons. The EWMA and LH methods were able to achieve reliable baseflow separation of the outcomes by selecting appropriate the filter parameters. Thus, the EWMA and LH methods can be used easily and reasonably among the digital filter methods that have one filter parameter.