Resumen
The picosecond optical parametric chirped pulse amplifier (ps-OPCPA) with double BBO arrangement can support the ultrabroad spectrum even under a relatively long pump pulse duration (~100 ps). In this work, five-wave-coupled equations taking into consideration different phase matching conditions between the parametric superfluorescence (PSF) and the signal are proposed to investigate the temporal contrast in ps-OPCPA schemes. Both the temporal contrast and the amplified spectrum are numerically analyzed in double BBO arrangements with four phase matching conditions. Numerical results show that the high temporal contrast and ultrabroad spectrum can be simultaneously realized by choosing the proper phase matching geometry in a double BBO arrangement. The numerical investigation here relaxes the requirement of very short pump pulses in ps-OPCPA, which can provide beneficial guidance for the design and construction of ps-OPCPA.