Redirigiendo al acceso original de articulo en 15 segundos...
Inicio  /  Future Internet  /  Vol: 14 Par: 5 (2022)  /  Artículo
ARTÍCULO
TITULO

Channel Characterization and SC-FDM Modulation for PLC in High-Voltage Power Lines

Jose Alberto Del Puerto-Flores    
José Luis Naredo    
Fernando Peña-Campos    
Carolina Del-Valle-Soto    
Leonardo J. Valdivia and Ramón Parra-Michel    

Resumen

Digital communication over power lines is an active field of research and most studies in this field focus on low-voltage (LV) and medium-voltage (MV) power systems. Nevertheless, as power companies are starting to provide communication services and as smart-grid technologies are being incorporated into power networks, high-voltage (HV) power-line communication has become attractive. The main constraint of conventional HV power-line carrier (PLC) systems is their unfeasibility for being migrated to wideband channels, even with a high signal-to-noise ratio (SNR). In this scenario, none of the current linear/non-linear equalizers used in single carrier schemes achieve the complete compensation of the highly dispersive conditions, which limits their operation to 4 kHz channels. In this paper, a new PLC-channel model is introduced for transmission lines incorporating the effects of the coupling equipment. In addition, the use of the single-carrier frequency-division modulation (SC-FDM) is proposed as a solution to operate PLC systems in a wide bandwidth, achieving transmission speeds above those of the conventional PLC system. The results presented in this paper demonstrate the superior performance of the SC-FDM-PLC over conventional PLC systems, obtaining a higher transmission capacity in 10 to 30 times.

 Artículos similares

       
 
Charlie Marshak, Marc Simard, Michael Denbina, Johan Nilsson and Tom Van der Stocken    
We present Orinoco, an open-source Python toolkit that applies the fast-marching method to derive a river delta channel network from a water mask and ocean delineation. We are able to estimate flow direction, along-channel distance, channel width, and ne... ver más

 
Victor Moënne-Loccoz, Isabelle Trébinjac, Nicolas Poujol and Pierre Duquesne    
The flow in the vaned diffuser of an aeronautical centrifugal compressor designed by Safran Helicopter Engines is analyzed through steady and unsteady pressure measurements at different rotation speeds. The analysis leads to the identification of differe... ver más

 
Hung-Pin Chiu, Jian-Ping Suen     Pág. 1 - 13
After Typhoon Morakot, dredging engineering was conducted while taking the safety of humans and structures into consideration, but partial stream reaches were formed in the multiple-channel sections in Cishan Stream because of anthropogenic and natural i... ver más
Revista: Water

 
Jichul Ryu, Won Seok Jang, Jonggun Kim, Joong Dae Choi, Bernard A. Engel, Jae E. Yang, Kyoung Jae Lim     Pág. 1 - 18
In this study, 52 asymptotic Curve Number (CN) regression equations were developed for combinations of representative land covers and hydrologic soil groups. In addition, to overcome the limitations of the original Long-term Hydrologic Impact Assessment ... ver más
Revista: Water

 
Khan Z. Jadoon, Samir Al-Mashharawi, Sherif M. Hanafy, Gerard T. Schuster and Thomas M. Missimer    
Wadi aquifers in Saudi Arabia historically have been recharged primarily by channel loss (infiltration) during floods. Historically, seasonal groundwater levels fluctuated from land surface to about 3 m below the surface. Agricultural irrigation pumping ... ver más
Revista: Water