Redirigiendo al acceso original de articulo en 19 segundos...
ARTÍCULO
TITULO

HESS in a Wind Turbine Generator: Assessment of Electric Performances at Point of Common Coupling with the Grid

Linda Barelli    
Dario Pelosi    
Dana Alexandra Ciupageanu    
Panfilo Andrea Ottaviano    
Michela Longo and Dario Zaninelli    

Resumen

Among Renewable Energy Sources (RES), wind energy is emerging as one of the largest installed renewable-power-generating capacities. The technological maturity of wind turbines, together with the large marine wind resource, is currently boosting the development of offshore wind turbines, which can reduce the visual and noise impacts and produce more power due to higher wind speeds. Nevertheless, the increasing penetration of wind energy, as well as other renewable sources, is still a great concern due to their fluctuating and intermittent behavior. Therefore, in order to cover the mismatch between power generation and load demand, the stochastic nature of renewables has to be mitigated. Among proposed solutions, the integration of energy storage systems in wind power plants is one of the most effective. In this paper, a Hybrid Energy Storage System (HESS) is integrated into an offshore wind turbine generator with the aim of demonstrating the benefits in terms of fluctuation reduction of the active power and voltage waveform frequency, specifically at the Point of Common Coupling (PCC). A MATLAB®/SimPowerSystems model composed of an offshore wind turbine interfaced with the grid through a full-scale back-to-back converter and a flywheel-battery-based HESS connected to the converter DC-link has been developed and compared with the case of storage absence. Simulations were carried out in reference to the wind turbine?s stress conditions and were selected?according to our previous work?in terms of the wind power step. Specifically, the main outcomes of this paper show that HESS integration allows for a reduction in the active power variation, when the wind power step is applied, to about 3% and 4.8%, respectively, for the simulated scenarios, in relation to more than 30% and 42% obtained for the no-storage case. Furthermore, HESS is able to reduce the transient time of the frequency of the three-phase voltage waveform at the PCC by more than 89% for both the investigated cases. Hence, this research demonstrates how HESS, coupled with renewable power plants, can strongly enhance grid safety and stability issues in order to meet the stringent requirements relating to the massive RES penetration expected in the coming years.

 Artículos similares

       
 
Carlos Matos, Pedro Cabrera, José A. Carta and Noemi Melián-Martel    
Water scarcity is a global problem that particularly affects islands located in arid regions or regions with limited water resources. This issue has prompted the development of non-conventional water sources such as fossil fuel-powered desalination syste... ver más

 
Fangdi Ye, Jijian Lian, Tianrun Xiao, Dongzhi Xiong, Haijun Wang, Yaohua Guo and Nan Shao    
To enhance the safety of the in-water sinking operation for an integrated system, including a bucket foundation (BF), tower, and rotor nacelle assembly (RNA), in complex marine environmental conditions, a model test of in-water sinking for an offshore wi... ver más

 
Shurong Peng, Lijuan Guo, Haoyu Huang, Xiaoxu Liu and Jiayi Peng    
The integration of large-scale wind power into the power grid threatens the stable operation of the power system. Traditional wind power prediction is based on time series without considering the variability between wind turbines in different locations. ... ver más
Revista: Applied Sciences

 
Younes Zekeik, Maria J. OrtizBevia, Francisco J. Alvarez-Garcia, Ali Haddi, Youness El Mourabit and Antonio RuizdeElvira    
Offshore wind energy is a promising resource for renewable energy development. Reanalysed wind data are unmatched by other wind data sources in providing a long-term assessment of wind power potential. In this study, 10 of the selected offshore locations... ver más

 
Fernando J. Ribeiro, João A. Peças Lopes, Filipe J. Soares and André G. Madureira    
Currently, the transmission system operators (TSOs) from Portugal and Spain do not procure a frequency containment reserve (FCR) through market mechanisms. In this context, a virtual power plant (VPP) that aggregates sources, such as wind and solar power... ver más
Revista: Applied Sciences