Seismic Capacity of R/C Buildings Retrofitted with a V-Bracing System Equipped with a Novel Laterally Layered Friction Damper

Bok-Gi Lee    
Jin-Young Kim    
Ju-Seong Jung and Kang-Seok Lee    

Resumen

This study proposed a novel V-bracing system equipped with a laterally layered friction damper (LLFD), which can supplement the shortcomings of conventional vibration control systems and is applicable to existing reinforced concrete (R/C) buildings. A material test was used to evaluate the material performance and energy dissipation capacity of this LLFD. Pseudo-dynamic testing was conducted on two-story frame specimens based on an existing R/C building with non-seismic details to verify the seismic retrofitting effects of applying the LLFD V-bracing system to existing R/C frames, i.e., the restoring force characteristics, energy dissipation capacity, and seismic response control capacity. Based on the results of the material and pseudo-dynamic tests, restoring characteristics were proposed for the non-linear dynamic analysis of a building (frame specimen) retrofitted with the LLFD V-bracing system. A non-linear dynamic analysis was conducted based on the proposed restoring force characteristics, and the results obtained were compared with the pseudo-dynamic test results. Finally, for evaluating the commercialization potential of the LLFD V-bracing system, a non-linear dynamic analysis was conducted on an existing R/C building with non-seismic details retrofitted with the system. The seismic retrofitting effect was verified by examining the seismic response load and displacement characteristics, energy dissipation capacity, and damper load and displacement response before and after seismic retrofitting. The study results showed that the R/C frame (building) with non-seismic details exhibited shear failure at a design basis earthquake scale of 200 cm/s2; however, light seismic damage could be expected for a frame (building) retrofitted with the LLFD V-bracing system. At a maximum considered earthquake scale of 300 cm/s2, insignificant seismic damage was also anticipated, thereby verifying the validity of the newly developed LLFD V-bracing system.

 Artículos similares

       
 
Panuwat Joyklad, Hafiz Ahmad Waqas, Abdul Hafeez, Nazam Ali, Ali Ejaz, Qudeer Hussain, Kaffayatullah Khan, Arissaman Sangthongtong and Panumas Saingam    
Many masonry structures are constructed with cement clay interlocking brick (CCIB) due to its added benefits. Recent research has demonstrated the vulnerability of brick masonry walls against seismic loading. Various strengthening materials and technique... ver más
Revista: Infrastructures

 
Melisa Herrera, Diego Sosa, Sigifredo Díaz and Jessica Thangjitham    
Current construction codes require detailed analyses for structural retrofitting, which must consider performance during seismic events. Therefore, the computational models used to evaluate existing infrastructure require nonlinear structural analysis an... ver más
Revista: Applied Sciences

 
Jiakang Li, Zhe Zhang, Lu Wang, Zhe Ma and Wenyuan Wang    
Aiming at the problem of excessive vertical vibration caused by seismic primary waves in jacket structures located in seismic zones in China, a new type of shear plate metal damper with upper and lower elliptical openings (SPA) is proposed in this paper.... ver más

 
Yves Reuland, Panagiotis Martakis and Eleni Chatzi    
Rapid post-earthquake damage assessment forms a critical element of resilience, ensuring a prompt and functional recovery of the built environment. Monitoring-based approaches have the potential to significantly improve upon current visual inspection-bas... ver más
Revista: Applied Sciences

 
Na He and Xianggang Zhang    
During the construction of a diversion tunnel, geological problems often include faults, fragile strata, hard rock formations, karst landforms, etc., which may have adverse effects on the excavation and construction of the diversion tunnel. Based on the ... ver más