Redirigiendo al acceso original de articulo en 17 segundos...
Inicio  /  Applied Sciences  /  Vol: 12 Par: 21 (2022)  /  Artículo
ARTÍCULO
TITULO

Seismic Vulnerability Evaluation of a Historical Masonry Tower: Comparison between Different Approaches

Manuela Scamardo    
Marco Zucca    
Pietro Crespi    
Nicola Longarini and Sara Cattaneo    

Resumen

Throughout the last few decades, the scientific community has paid great attention to the structural safety of historical masonry constructions, which have high vulnerability with respect to seismic activities. Masonry towers are very widespread in Italy and represent an important part of the built heritage to be preserved. Different numerical methods with different levels of refinement were developed in the literature to evaluate their seismic performance. The present study shows a practical application of the seismic vulnerability evaluation of a masonry tower using different approaches. The aim is to provide practical suggestions to engineers for the successful evaluation of the performance of masonry towers under seismic loads. An in situ survey was performed to characterize the geometry of the structure and its constitutive material. All the collected information was introduced in a building information model, later used to generate different finite element models for the structural analyses. The global capacity of the structure was evaluated using three different models with different levels of complexity: the first simplified model is made of beam elements with cross-sections discretized in fibers; the second model is made of shell elements and uses a concrete damage plasticity model to describe the nonlinear masonry behavior; the third model adopts solid elements with a concrete smeared crack constitutive law. A preliminary eigen-frequency analysis is performed on the shell model to obtain some basic information about the structural behavior. Nonlinear static analyses were carried out for each model to understand the response of the tower under seismic loads, highlighting the main differences between the approaches. The behavior factor was evaluated on the basis of the analyses results and compared with the ones suggested by the Italian building code. The results showed that the towers do not satisfy the seismic demand required by the standards for all the considered models. Furthermore, the behavior factor calculated according to the Italian design code is overestimated, while the one evaluated by the simplified model is underestimated due to the neglection of the shear behavior. From all the analyzed configurations, the shell model resulted as a good compromise between reliable results and computation efficiency.

 Artículos similares

       
 
Irene Puncello and Silvia Caprili    
The relevant losses determined by recent earthquakes stressed the vulnerability of historical masonry constructions towards horizontal seismic actions, therefore highlighting the need for reliable approaches for the structural assessment and following re... ver más
Revista: Applied Sciences

 
Ho-Jin Baek, Ju-Seong Jung, Kang-Seok Lee and Bok-Gi Lee    
This study proposes a concrete-filled tube composite strengthening system (CCSS), which is a new concept that can improve and supplement the vulnerability of existing CFT seismic strengthening methods. The CCSS seismic reinforcement method is easy to con... ver más
Revista: Applied Sciences

 
Panuwat Joyklad, Hafiz Ahmad Waqas, Abdul Hafeez, Nazam Ali, Ali Ejaz, Qudeer Hussain, Kaffayatullah Khan, Arissaman Sangthongtong and Panumas Saingam    
Many masonry structures are constructed with cement clay interlocking brick (CCIB) due to its added benefits. Recent research has demonstrated the vulnerability of brick masonry walls against seismic loading. Various strengthening materials and technique... ver más
Revista: Infrastructures

 
Alexandros Tsipianitis and Yiannis Tsompanakis    
Base isolation of liquid storage tanks has proven to be an efficient seismic protection measure, leading to a drastic reduction of a superstructure?s distress. However, many such tanks are located near seismic tectonic faults, which generate strong pulse... ver más
Revista: Infrastructures

 
?eljana Nikolic, Elena Benvenuti and Luka Runjic    
The seismic risk assessment of existing urban areas provides important information for the process of seismic risk reduction in different phases of planning and emergency management. Between different large-scale assessment approaches, a vulnerability in... ver más
Revista: Applied Sciences