Resumen
Reinforced concrete is the most commonly used material in the construction industry. However, one disadvantage of reinforced concrete is that environmental factors cause materials to penetrate the concrete and cause steel bar corrosion. Rebar corrosion increases its volume significantly by approximately 3?6 times, which lowers concrete?rebar adhesion. This severely affects the serviceability and durability of concrete structures. The economic and social impacts of such deterioration are extremely large. To reduce corrosion, glass fiber-reinforced plastics (GFRP) and carbon fiber-reinforced plastics (CFRP) can be applied to concrete. The rebar?concrete bond strength is an important factor to be considered while applying GFRP and CFRP. Thus, we experimentally investigated the adhesion strength of GFRP and CFRP in relation to the strength of concrete and water?cement ratio according to ASTM C 234 to correlate the data for the development of GFRP and CFRP as substitutes for deformed reinforcing bars. The results showed that a lower water?cement ratio yielded higher compressive strength and bond strength; the bond strength of GFRP was approximately 23% lower than that of CFRP. The coating of the rebar surface required for GFRP and CFRP application in reinforced concrete structures ought to be investigated in the future.