Redirigiendo al acceso original de articulo en 18 segundos...
Inicio  /  Environments  /  Vol: 5 Núm: 6 Par: June (2018)  /  Artículo
ARTÍCULO
TITULO

Performance of Reverse Osmosis Membranes in the Treatment of Flue-Gas Desulfurization (FGD) Wastewaters

Carmela Conidi    
Francesca Macedonio    
Pietro Argurio    
Alfredo Cassano and Enrico Drioli    

Resumen

Reverse osmosis (RO) was studied to reduce salinity of flue gas desulfurization (FGD) wastewaters after softening with Na2CO3·H2O and ultrafiltration (UF). Two commercial thin film composite polyamide RO membranes (SWC-2540 and ESPA-2540, from Hydranautics) in spiral-wound configuration were tested and their performance in terms of salinity reduction as well as permeate flux, fouling index and water recovery was evaluated. Experimental runs were performed according to the feed and bleed configuration in selected operating conditions. For the SWC-2540 membrane experiments were also performed in total recycle configuration in order to evaluate the effect of operating pressure on permeate flux and quality. Experimental results indicated that the SWC-2540 membrane showed a better performance in the rejection of ions: Mg2+ ions were completely rejected, while the rejection towards monovalent ions such as Na+ was of about 95.5%. The ESPA-2540 membrane showed rejections towards Ca2+ and Mg2+ higher than 86.5% whilst the observed rejection towards Na+ was of 80%. For the SWC-2540 membrane an increased rejection for Ca2+ and Na+ ions was observed by increasing the operating pressure in the range 16-50 bar. Mg2+ ions were totally rejected independently by the operating pressure.

 Artículos similares

       
 
Cheng Zhu, Shaoqi Wang, Na He, Hui Sun, Linjuan Xu and Filip Gurkalo    
To improve the accuracy of debris flow forecasts and serve as disaster prevention and mitigation, an accurate and intelligent early warning method of debris flow initiation based on the IGWO-LSTM algorithm is proposed. First, the entropy method is employ... ver más
Revista: Water

 
Miles Schelling, Kavita Patil and Thomas B. Boving    
This study demonstrates that an induced bank filter (IBF) system can treat raw water polluted with Escherichia coli (E. coli) bacteria. Similar to riverbank filtration (RBF), induced or reversed bank filtration relies on natural processes to clean water,... ver más
Revista: Water

 
Huan Ni, Jocelyn Chanussot, Xiaonan Niu, Hong Tang and Haiyan Guan    
The large-scale variation issue in high-resolution aerial images significantly lowers the accuracy of segmenting small objects. For a deep-learning-based semantic segmentation model, the main reason is that the deeper layers generate high-level semantics... ver más

 
Jiafan Wang, Jorgelina Farias, Abhishek Tiwary, George Chi Tangyie and Katherine Huddersman    
Bisphenol A (BPA) is a well-known endocrine disruptor in the environment which is not readily oxidised during wastewater treatment at Municipal Authorities. The aim of this work is to evaluate the environmental value of the wastewater treatment of a nove... ver más
Revista: Water

 
Bijian Jian, Chunbo Ma, Dejian Zhu, Yixiao Sun and Jun Ao    
Imaging through a wavy water?air interface is challenging since light rays are bent by unknown amounts, leading to complex geometric distortions. Considering the restoration of instantaneous distorted images, this paper proposes an image recovery model v... ver más
Revista: Future Internet