Redirigiendo al acceso original de articulo en 21 segundos...
Inicio  /  Water Research  /  Vol: 103 Par: 0 (2016)  /  Artículo
ARTÍCULO
TITULO

Drinking water contaminants from epoxy resin-coated pipes: A field study

Johanna Rajasärkkä    
Marek Pernica    
Jan Kuta    
Joná? La?nák    
... Ludek Bláha    

Resumen

Rehabilitation of aged drinking water pipes is an extensive renovation and increasingly topical in many European cities. Spray-on-lining of drinking water pipes is an alternative cost-effective rehabilitation technology in which the insides of pipes are relined with organic polymer. A commonly used polymer is epoxy resin consisting of monomer bisphenol A (BPA). Leaching of BPA from epoxy lining to drinking water has been a concern among public and authorities. Currently epoxy lining is not recommended in some countries. BPA leaching has been demonstrated in laboratory studies but the behavior and ageing process of epoxy lining in situ is not well known. In this study 6 locations with different age epoxy linings of drinking water pipes done using two distinct technologies were studied. While bisphenol F, 4-n-nonylphenol, and 4-t-octylphenol were rarely found and in trace concentrations, BPA was detected in majority of samples. Pipes lined with the older technology (LSE) leached more BPA than those with more recent technology (DonPro): maxima in cold water were 0.25 µg/L and 10 ng/L, respectively. Incubation of water in pipes 8?10 h prior to sampling increased BPA concentration in cold water 1.1?43-fold. Hot water temperature caused even more BPA leaching - at maximum 23.5 µg/L. The influence of ageing of epoxy lining on BPA leaching on could be shown in case of LSE technology: locations with 8?9 years old lining leached 4?20-fold more BPA compared to a location with 2-year-old lining. Analysis of metals showed that epoxy lining can reduce especially iron concentration in water. No significant burden to water could be shown by the analyzed 72 volatile organic compounds, including epichlorhydrin, precursor used in epoxy resin. Estrogenicity was detected in water samples with the highest BPA loads. Comparable responses of two yeast bioreporters (estrogen receptor a and BPA-targeted) indicated that bisphenol-like compounds were the main cause of estrogenicity. Compared to the estimated average daily BPA exposure, additional BPA load via cold drinking water in the studied locations was low, maximum 8.7%. However, hot water should also be considered as exposure source due to higher BPA concentrations. Epoxy lined locations should be monitored in future in order to evaluate ageing process and control increasing leaching of potentially harmful chemicals.

 Artículos similares

       
 
Mmasabata Dolly Molekoa, Ram Avtar, Pankaj Kumar, Huynh Vuong Thu Minh and Tonni Agustiono Kurniawan    
Despite being a finite resource, both the quality and quantity of groundwater are under tremendous pressure due to rapid global changes, viz. population growth, land-use/land-cover changes (LULC), and climate change. The 6th Sustainable Development Goal ... ver más
Revista: Water

 
Husnain Haider, Mohammed Hammed Alkhowaiter, Md. Shafiquzzaman, Saleem S. AlSaleem, Meshal Almoshaogeh and Fawaz Alharbi    
Original Canadian Council of Minster of the Environment Water Quality Index (CCME WQI) is being used for assessing the water quality of surface water sources and distribution systems on a case by case basis. Its full potential as a management tool for co... ver más
Revista: Water

 
Tienan Li, Xueting Zeng, Cong Chen, Xiangmin Kong, Junlong Zhang, Ying Zhu, Fan Zhang and He Dong    
In this study, an initial water-rights allocation (IWRA) model is proposed for adjusting the traditional initial water-rights empowerment model based on previous water intake permits, with the aim of improving the productivity of water resources under po... ver más
Revista: Water

 
S. Johana Grajales-Mesa and Grzegorz Malina    
This study evaluates, under field conditions, the efficiency of a permeable reactive barrier (PRB) with compost and brown coal to remove trichloroethylene (TCE) (109 µg/L) from contaminated groundwater. Three stainless steel boxes (1.2 × 0.5 × 0.5 m) wit... ver más
Revista: Water

 
Masoud Jafari Shalamzari, Wanchang Zhang, Atefeh Gholami and Zhijie Zhang    
Site selection for runoff harvesting at large scales is a very complex task. It requires inclusion and spatial analysis of a multitude of accurately measured parameters in a time-efficient manner. Compared with direct measurements of runoff, which is tim... ver más
Revista: Water