Redirigiendo al acceso original de articulo en 18 segundos...
Inicio  /  Water Research  /  Vol: 125 Par: 0 (2017)  /  Artículo
ARTÍCULO
TITULO

CO2 saturated water as two-phase flow for fouling control in reverse electrodialysis

J. Moreno    
N. de Hart    
M. Saakes    
K. Nijmeijer    

Resumen

When natural feed waters are used in the operation of a reverse electrodialysis (RED) stack, severe fouling on the ion exchange membranes and spacers occurs. Fouling of the RED stack has a strong influence on the gross power density output; which can decrease up to 50%. Moreover, an increase in the pressure loss occurs between the feed water inlet and outlet, increasing the pumping energy and thus decreasing the net power density that can be obtained. In this work, we extensively investigated the use of CO2 saturated water as two-phase flow cleaning for fouling mitigation in RED using natural feed waters. Experiments were performed in the REDstack research facility located at the Afsluitdijk (the Netherlands) using natural feed waters for a period of 60 days. Two different gas combinations were experimentally investigated, water/air sparging and water/CO2 (saturated) injection. Air is an inert gas mixture and induces air sparging in the stack. In the case of CO2, nucleation, i.e. the spontaneous formation of bubbles, occurs at the spacer filaments due to depressurization of CO2 saturated water, inducing cleaning. Results showed that stacks equipped with CO2 saturated water can produce an average net power density of 0.18 W/m2 under real fouling conditions with minimal pre-treatment and at a low outside temperature of only 8 °C, whereas the stacks equipped with air sparging could only produce an average net power density of 0.04 W/m2. Electrochemical impedance spectroscopy measurements showed that the stacks equipped with air sparging increased in stack resistance due to the presence of stagnant bubbles remaining in the stack after every air injection. Furthermore, the introduction of CO2 gas in the feed water introduces a pH decrease in the system (carbonated solution) adding an additional cleaning effect in the system, thus avoiding the use of environmentally unwanted cleaning chemicals.

 Artículos similares

       
 
Ziran Zhang and Maosheng Zhang    
Describing the hydraulic conductivity of unsaturated soil is very important in predicting water transport. Most current models have complex forms and generally need to be calibrated by the measured unsaturated hydraulic conductivity curve. A simple model... ver más
Revista: Applied Sciences

 
Takahiro Yoshikawa and Toshihiro Noda    
Immense liquefaction damage was observed in the 2011 off the Pacific coast of Tohoku Earthquake. It was reported that, in Chiba Prefecture, Japan, the main shock oozed muddy water from the sandy ground and the aftershock which occurred 29 min after the m... ver más
Revista: Water

 
Z. Jason Hou, Nicholas D. Ward, Allison N. Myers-Pigg, Xinming Lin, Scott R. Waichler, Cora Wiese Moore, Matthew J. Norwood, Peter Regier and Steven B. Yabusaki    
The influence of coastal ecosystems on global greenhouse gas (GHG) budgets and their response to increasing inundation and salinization remains poorly constrained. In this study, we have integrated an uncertainty quantification (UQ) and ensemble machine ... ver más
Revista: Water

 
Aaron A. Akin, Gia Nguyen and Aleksey Y. Sheshukov    
Soil erosion by water on agricultural hillslopes leads to numerous environmental problems including reservoir sedimentation, loss of agricultural land, declines in drinking water quality, and requires deep understanding of underlying physical processes f... ver más
Revista: Water

 
Bicheng Zhou, Anatoly V. Brouchkov and Jiabo Hu    
Frost heaving in soils is a primary cause of engineering failures in cold regions. Although extensive experimental and numerical research has focused on the deformation caused by frost heaving, there is a notable lack of numerical investigations into the... ver más
Revista: Water