Redirigiendo al acceso original de articulo en 15 segundos...
Inicio  /  Energies  /  Vol: 10 Núm: 7 Par: July (2017)  /  Artículo
ARTÍCULO
TITULO

Pole-to-Ground Fault Analysis and Fast Protection Scheme for HVDC Based on Overhead Transmission Lines

Shimin Xue    
Jie Lian    
Jinlong Qi and Boyang Fan    

Resumen

Flexible direct current (DC) transmission network technology is an effective method for large capacity clean energy access to power grids, but the DC short-circuit fault detection for it is a difficult problem. In this paper, the pole-to-ground fault transient characteristics in a multi-terminal DC power grid, based on overhead transmission lines and DC circuit breakers, are analyzed firstly. Then, a fast protection scheme is proposed according to the fault transient characteristics. Only local information is utilized for fault detection and location in the proposed scheme. Moreover, the scheme is verified to have the advantages of fast action speed, high reliability and the ability to resist the transition resistance. A four terminal DC power grid model based on actual engineering parameters is established in PSCAD/EMTDC, and the validity of the protection scheme under different fault conditions is verified by simulation results.

 Artículos similares

       
 
Huiyuan Liu, Kehan Xu, Zhe Zhang, Wei Liu and Jianyong Ao    
With the substantial increase in the capacity of grid-connected photovoltaic (PV) power, the adverse effects of its complex fault characteristics on grid relay protection are increasingly highlighted. Based on the introduction of the topology and the con... ver más
Revista: Energies

 
Photovoltaic (PV) power stations tend to have a relatively weak infeed characteristic, unlike conventional synchronous generators. The limited overcurrent capability of power electronic devices and the controllability of grid-connected inverters mean tha... ver más
Revista: Energies

 
Ultra-high voltage direct current (UHVDC) systems under hierarchical connection schemes (HCSs) linked to AC grids with different voltage levels (500 and 1000 kV) have been a great concern for power utilities to transfer bulk power. They have some operati... ver más
Revista: Energies

 
Shaohua Hu, Xinlong Zhou, Yi Luo and Guang Zhang    
Due to high water pressure in the concrete reinforced hydraulic tunnels, surrounding rocks are confronted with nonlinear seepage problem in the pumped storage power station. In this study, to conduct nonlinear seepage numerical simulation, a nonlinear se... ver más
Revista: Energies

 
Min Lu, Yu Chen, Debin Zhang, Jingyuan Su and Yong Kang    
The Brushless Doubly Fed Induction Generator (BDFIG) has huge potential for wind power systems due to its high reliability and low maintenance cost. To add inertia for system stability enhancement, as well as to maintain the uninterrupted operation durin... ver más