Redirigiendo al acceso original de articulo en 17 segundos...
Inicio  /  Water  /  Vol: 8 Núm: 3 Par: 0 (2016)  /  Artículo
ARTÍCULO
TITULO

Bacteria Removal from Stormwater Runoff Using Tree Filters: A Comparison of a Conventional and an Innovative System

Laura A. Schifman    
Varun K. Kasaraneni    
Ryan K. Sullivan    
Vinka Oyanedel-Craver    
Thomas B. Boving    

Resumen

Non-point source pollution of stormwater contributes high contaminant loads into surface water bodies and poses a threat to the ecosystem, public health and economy. Although (pre)treatment standards have not been introduced at the federal level, Rhode Island (RI) has set minimal contaminant reduction standards for stormwater using structural best management practices (BMP). As BMP performance depends highly on geographical location and climate, and the Northeastern United States experiences broad ranges of temperatures throughout the year along with long intermittent periods between precipitation events, stormwater treatment can be challenging. In this field study, two tree filters were evaluated: a conventional unit (CTF) with sand/shale mix as filter media, and a modified tree filter (ITF) with an added layer of red cedar wood chips amended with 3-(trihydroxysilyl)propyldimethyloctadecyl ammonium chloride. Both BMPs were monitored for 346 days primarily for Escherichia coli and polycyclic aromatic hydrocarbons (PAH). Both tree filters met or outperformed RI?s standards for bacteria removal (60%) and TSS (85%), making them a good choice for BMP use in this climate. Total suspended solids, E. coli, PAHs, nitrate, and phosphate removal is higher in ITF. A controlled field scale tracer test using E. coli confirmed these results.

 Artículos similares

       
 
Bowei Zhang, Changsheng Zhao, Ting Liu and Xiaokai Wang    
As the problem of eutrophication of water bodies and nitrate pollution of surface and groundwater is becoming more and more prominent, deep denitrification of wastewater can effectively reduce the amount of nitrate nitrogen (NO3--N) discharged into natur... ver más
Revista: Water

 
Joanna Kazimierowicz, Marcin Debowski and Marcin Zielinski    
The liquid fraction from the dewatering of digested sewage sludge (LF-DSS) represents a major processing complication for wastewater treatment facilities, thus necessitating new and effective methods of LF-DSS neutralization. This pilot-scale study exami... ver más
Revista: Applied Sciences

 
Mohammad I. Al-Qubaisey, Rita M. Khounganian, Saeed A. Syed and Sameh A. Saif    
In some cases, titanium plates could be a reservoir for harboring bacteria resulting in challenging cases of infection. Current estimates indicate that 10?12% of plates require removal due to infection, exposure, pain, and discomfort. The present investi... ver más
Revista: Applied Sciences

 
Ruoting Gao, Ronglin Sun, Chunfang Zhang and Wenjie Zhang    
Filtration backwashing is necessary for the effective operation of membrane modules, and intermittent aeration helps to remove nutrients, which can save energy and effectively control the occurrence of membrane contamination. In this study, membrane cont... ver más
Revista: Water

 
Álef Luan de Souza Pereira, Cristina Celia Silveira Brandão, Yovanka Pérez Ginoris and Carla Patrícia Pereira Alves    
Monitoring the removal of Cryptosporidium oocysts in water treatment plants is a challenge, particularly in developing countries, and the use of surrogates has proven necessary. Two surrogates already investigated and recognized by the scientific communi... ver más
Revista: Water