Air Leakage of Joints Filled with Polyurethane Foam

Resumen

Air leakage through the building envelope joints is usually one of the main reasons why airtightness targets are not achieved. The objective of this study was to analyse the air leakage of joints filled with polyurethane foam and its influencing factors. Wooden test specimens (54 in total) with planed, sawn and plastic-coated cavities and two cavity thicknesses were filled with three different polyurethane foams and tested according to standard EN 12114. The surface type and thickness of the joint had a significant effect on the air leakage of joints filled with polyurethane foam. In laboratory conditions, a consistent and very low air leakage rate was obtained with planed timber surfaces. Joints with plastic-coated and sawn timber surfaces performed worse, on average, by a factor of two or more and contributed to very variable airtightness, with up to 28% and 50% of the test specimens failing the airtightness testing. On the basis of the high ‘failure rate’, polyurethane foam may classify as a not completely trustworthy solution in guaranteeing the airtightness of construction joints. A comparison of estimated and previously measured overall airtightness of an entire building envelope showed dependency on ‘failure rate’ rather than on average measured leakage rate.

 Artículos similares

       
 
Social housing dating from the postwar years through the end of the twentieth century is one of the major stores of European cities’ residential stock. As it is generally characterised by a poor thermal performance and an inefficient control of ene... ver más
Revista: Sustainability

 
Prakash Devkota and Joonam Park    
The super-speed tube transport (SSTT) system, which enables high-speed transportation in a partially vacuumed tube by minimizing the air resistance, is drawing attention as a next-generation transportation system. To evaluate the applicability of concret... ver más
Revista: Infrastructures

 
Mark Bassett and Greg Overton    
Residential buildings are now better engineered to manage rainwater following the leaking building problem in New Zealand. The next challenge is to improve the weathertightness of medium-rise buildings which often use joint details widely applied on low-... ver más
Revista: Buildings

 
M. M. Biliaiev,O. V. Koptyla     Pág. 6 - 11
A 2D computer model to simulate air pollution after liquid ammonia leakage accidents has been developed. The model is based on numeric integration of diffusion equation and convectional transfer of the impurity. The calculation has been performed accordi... ver más