Redirigiendo al acceso original de articulo en 17 segundos...
Inicio  /  Water  /  Vol: 9 Núm: 2 Par: 0 (2017)  /  Artículo
ARTÍCULO
TITULO

Small Scale Direct Potable Reuse (DPR) Project for a Remote Area

Jianhua Zhang    
Mikel C. Duke    
Kathy Northcott    
Michael Packer    
Mayumi Allinson    
Graeme Allinson    
Kiwao Kadokami    
Jace Tan    
Sebastian Allard    
Jean-Philippe Croué    
Adrian Knight    
Peter J. Scales    
Stephen R. Gray    

Resumen

An Advanced Water Treatment Plant (AWTP) for potable water recycling in Davis Station Antarctica was trialed using secondary effluent at Selfs Point in Hobart, Tasmania, for nine months. The trials demonstrated the reliability of performance of a seven barrier treatment process consisting of ozonation, ceramic microfiltration (MF), biologically activated carbon, reverse osmosis, ultra-violet disinfection, calcite contactor and chlorination. The seven treatment barriers were required to meet the high log removal values (LRV) required for pathogens in small systems during disease outbreak, and on-line verification of process performance was required for operation with infrequent operator attention. On-line verification of pathogen LRVs, a low turbidity filtrate of approximately 0.1 NTU (Nephelometric Turbidity Unit), no long-term fouling and no requirement for clean-in-place (CIP) was achieved with the ceramic MF. A pressure decay test was also reliably implemented on the reverse osmosis system to achieve a 2 LRV for protozoa, and this barrier required only 2?3 CIP treatments each year. The ozonation process achieved 2 LRV for bacteria and virus with no requirement for an ozone residual, provided the ozone dose was >11.7 mg/L. Extensive screening using multi-residue gas chromatography?mass spectrometry (GC?MS) and liquid chromatography?mass spectrometry (LC?MS) database methods that can screen for more than 1200 chemicals found that few chemicals pass through the barriers to the final product and rejected (discharge) water streams. The AWTP plant required 1.93 kWh/m3 when operated in the mode required for Davis Station and was predicted to require 1.27 kWh/m3 if scaled up to 10 ML/day. The AWTP will be shipped to Davis Station for further trials before possible implementation for water recycling. The process may have application in other small remote communities.

 Artículos similares

       
 
Janis Kramens, Megija Valtere, Guntars Krigers, Vladimirs Kirsanovs and Dagnija Blumberga    
The EU?s energy targets are to achieve at least 32% renewables in the energy mix by 2030. Part of the solution is strengthening consumer rights by empowering individuals to generate their own electricity. The aim of this study was to identify the most su... ver más

 
Yiming Mo, Lei Wang, Wenqing Hong, Congzhen Chu, Peigen Li and Haiting Xia    
The intrusion of foreign objects on airport runways during aircraft takeoff and landing poses a significant safety threat to air transportation. Small-scale Foreign Object Debris (FOD) cannot be ruled out on time by traditional manual inspection, and the... ver más
Revista: Applied Sciences

 
Feng Guo, Hongbing Ma, Liangliang Li, Ming Lv and Zhenhong Jia    
In the realm of maritime target detection, infrared imaging technology has become the predominant modality. Detecting infrared small ships on the sea surface is crucial for national defense and maritime security. However, the challenge of detecting infra... ver más

 
Jifeng Zhu, Xiaohe Pan, Zheng Peng, Mengzhuo Liu, Jingqian Guo and Jun-Hong Cui    
The establishment of the Underwater Internet of Things (UIoT) and the realization of interconnection between heterogeneous underwater intelligent devices are urgent global challenges. Underwater acoustic networking is the most suitable technology to achi... ver más

 
Mohamed Ben Rhouma, Azer Maazoun, Aldjabar Aminou, Bachir Belkassem, Ignaas Vandenbruwane, Tine Tysmans and David Lecompte    
Reinforced concrete (RC) columns, being axial-bearing components in buildings, are susceptible to damage and failure when subjected to blast loading. The failure of these columns can trigger a progressive collapse in targeted buildings. The primary objec... ver más
Revista: Buildings