Redirigiendo al acceso original de articulo en 21 segundos...
ARTÍCULO
TITULO

Film Cooling Effectiveness Downstream of Trailing Edge Slots Including Cutback Surface Protuberances

 Artículos similares

       
 
Manuel Wilhelm and Heinz-Peter Schiffer    
Rotor tip film cooling is investigated at the Large Scale Turbine Rig, which is a 1.5-stage axial turbine rig operating at low speeds. Using pressure sensitive paint, the film cooling effectiveness η" role="presentation">??? ? at a squealer-ty... ver más

 
Tommaso Bacci, Alessio Picchi and Bruno Facchini    
Shaped holes are considered as an effective solution to enhance gas turbine film-cooling performance, as they allow to increase the coolant mass-flux, while limiting the detrimental lift-off phenomena. A great amount of work has been carried out in past ... ver más

 
Lorenzo Cocchi, Alessio Picchi and Bruno Facchini    
Experimental activity has been performed to study different impingement cooling schemes in static and rotating conditions. Geometry replicates a leading-edge cold bridge system, including a radial supply channel and five rows of film-cooling and showerhe... ver más

 
Alexander V. Murray, Peter T. Ireland, Tsun Holt Wong, Shaun Wei Tang and Anton J. Rawlinson    
The continuing rise in turbine entry temperatures has necessitated the development of ever-more advanced cooling techniques. Effusion cooling is an example of such a system and is characterised by a high density of film cooling holes that operate at low ... ver más

 
Seung Il Baek and Savas Yavuzkurt    
Revista: Inventions