Redirigiendo al acceso original de articulo en 16 segundos...
ARTÍCULO
TITULO

Improvement of the installation with an extended barrel of cranked type used for fire extinguishing by gel-forming compositions

Kostiantyn Ostapov    
Igor Kirichenko    
Yurii Senchykhin    
Volodymyr Syrovyi    
Darya Vorontsova    
Anatoly Belikov    
Alexey Karasev    
Hanna Klymenko    
Ekaterina Rybalka    

Resumen

Extinguishing fires with gel-forming compositions was found to be a promising direction of increasing the extinguishing efficiency, especially at multi-storey buildings and facilities for different functional purposes, because it makes it possible to prevent unintended damage from flooding the lower floors.To extinguish fires at residential and industrial buildings rapidly, the new installation for fire extinguishing by gel-forming compositions was proposed. The rational use of the fire-extinguishing capacity of gel-forming compositions in it is achieved through the application of a cranked extended barrel with a special mixer and a sprayer. This new installation enables extinguishing by gel-forming compositions from the distance of 3?5 m to the fire site, ensuring safety of a firefighter-rescuer.The full-scale sample of the original two-cranked barrel-sprayer of the portable installation was constructed, manufactured, and tested. By performing experimental research, it was proven that its use, due to its compactness in the folded state and the ease of unfolding into operating position, provides convenience of transportation and operation efficiency under rapidly changing conditions of a fire, especially in high-rise buildings.Feeding gel-forming compositions in the finely sprayed form decreases their consumption for extinguishing fires by 1.5 times, compared with the previously proposed technical solutions.To determine the effective value of dispersion and intensity of spraying gel-forming compositions in mathematical models of consumption for extinguishing the simulated fire and the time to extinguish it, we used second degree polynomials. Unknown coefficients were determined by the standard least square method. As a result, the rational values of the diameter of droplets (1 mm) and intensity of feeding (0.6 l/s) of gel-forming compositions were determined, which ensured the technical optimum of their use. Thus, it was found that the parameters of extinguishing the simulated fire 1A by the finely dispersed gel-forming compositions correspond to the total consumption of 2.5 kg, which is 3.5 times less compared with water

 Artículos similares

       
 
Yang Liu, Ziyuan Xu, Huafei Du and Mingyun Lv    
Stratospheric airships with a solar array have demonstrated overwhelming superiority in many aspects, such as earth observation, meteorological survey, and communication relay. The solar array supplies sufficient power for the airship to be in flight for... ver más
Revista: Aerospace

 
Chunrui Liu, Lidong He, Xingyun Jia, Haozhe Zhu, Tao Chen and Wenhao Wang    
The rotary seal is a key component of the aero engine. Under actual working conditions, most rotary seals always operate in an eccentric state (caused by installation errors), and when a large eccentricity occurs, it may lead to a large amount of gas lea... ver más
Revista: Aerospace

 
Khaled Shaaban and Mohammed Alsoub    
Developing countries are continuously upgrading their transportation systems. The latest improvement in Qatar, a fast-developing country in the Middle East, was the installation of dynamic message signs (DMS) and lane control signs (LCS). These signs wer... ver más
Revista: Infrastructures

 
Luis E. Camilo Rosado, P. Amparo López-Jiménez, Francisco-Javier Sánchez-Romero, Pilar Conejos Fuertes and Modesto Pérez-Sánchez    
Sustainable development has been an idea raised in recent years. The results are related to the improvement and the use of new technologies to maximize efficiency in water management. However, energy consumption has been increasing as a consequence of ne... ver más
Revista: Water

 
Rafael Baeza and Juana I. Contreras    
Emitter clogging is a problem in drip irrigation systems, and it is accentuated when using reclaimed water. The objective of this work was to evaluate the different commercial models of drippers used for irrigation with reclaimed water in greenhouse hort... ver más
Revista: Water