Seismic Vulnerability Assessment Using Rapid Visual Screening: Case Study of Educational Facility Buildings of Jenderal Soedirman University, Indonesia

Yanuar Haryanto    
Hsuan-Teh Hu    
Ay Lie Han    
Banu Ardi Hidayat    
Arnie Widyaningrum    
Prisca Evelyn Yulianita    

Resumen

Earthquakes are natural phenomena occurring in various parts of the globe. Severe earthquakes caused substantial loss of life and property when nearly populated districts. Although some progress has been made in the area of seismic prediction, earthquakes in time, magnitude or location can not be estimated correctly. The primary method of reducing casualties is therefore to build seismic resistant structures. Current earthquakes show that the old houses, which are not intended to withstand earthquakes, have been harmed rather than the structures intended according to seismic regulations. Many current structures in Indonesia were intended only without seismic provisions to withstand the gravity loads. There is a need to study these buildings' vulnerability in order to prevent a severe danger. A Rapid Visual Screening (RVS) technique is conducted in this study to determine a Final Level 1 Score, SL1, for Jenderal Soedirman University, Indonesia?s educational facility buildings. In nine constructions situated in Purwokerto and Purbalingga, the method was implemented. Moreover, the final SL1 score is an estimate of the collapse probability if an earthquake occurs with ground motions called the maximum considered earthquake targeted risk, MCER. These score estimates are based on restricted observed and analytical information, thus the probability of collapse is therefore an approximation.

 Artículos similares

       
 
Irene Puncello and Silvia Caprili    
The relevant losses determined by recent earthquakes stressed the vulnerability of historical masonry constructions towards horizontal seismic actions, therefore highlighting the need for reliable approaches for the structural assessment and following re... ver más
Revista: Applied Sciences

 
Ho-Jin Baek, Ju-Seong Jung, Kang-Seok Lee and Bok-Gi Lee    
This study proposes a concrete-filled tube composite strengthening system (CCSS), which is a new concept that can improve and supplement the vulnerability of existing CFT seismic strengthening methods. The CCSS seismic reinforcement method is easy to con... ver más
Revista: Applied Sciences

 
Panuwat Joyklad, Hafiz Ahmad Waqas, Abdul Hafeez, Nazam Ali, Ali Ejaz, Qudeer Hussain, Kaffayatullah Khan, Arissaman Sangthongtong and Panumas Saingam    
Many masonry structures are constructed with cement clay interlocking brick (CCIB) due to its added benefits. Recent research has demonstrated the vulnerability of brick masonry walls against seismic loading. Various strengthening materials and technique... ver más
Revista: Infrastructures

 
Alexandros Tsipianitis and Yiannis Tsompanakis    
Base isolation of liquid storage tanks has proven to be an efficient seismic protection measure, leading to a drastic reduction of a superstructure?s distress. However, many such tanks are located near seismic tectonic faults, which generate strong pulse... ver más
Revista: Infrastructures

 
?eljana Nikolic, Elena Benvenuti and Luka Runjic    
The seismic risk assessment of existing urban areas provides important information for the process of seismic risk reduction in different phases of planning and emergency management. Between different large-scale assessment approaches, a vulnerability in... ver más