Redirigiendo al acceso original de articulo en 24 segundos...
Inicio  /  Instruments  /  Vol: 7 Par: 3 (2023)  /  Artículo
ARTÍCULO
TITULO

A Novel, Rapid Response Renewable Biopolymer Neutron and Gamma Radiation Solid-State Detector for Dosimetry and Nuclear Reactor Flux-Power Mapping

Wen Jiang    
True Miller    
Troy Barlow    
Nathan Boyle and Rusi P. Taleyarkhan    

Resumen

A novel solid-state neutron and gamma radiation monitor-dosimeter based on biopolymer polylactic acid (PLA) is presented. The resulting detector (PLAD) technology takes advantage of property changes of the renewable PLA resin when subject to ionizing nuclear radiation. A simple yet rapid and accurate (±10%) low-cost (<$0.01/detector) mass loss upon dissolution (MLD) technique was successfully developed; MLD is based on a simple mass balance for discerning neutron and/or gamma doses using small (40 mg, ~4 mm diameter) ultra-low-cost (<$0.01) resin beads via dissolution in acetone. The GammaCellTM Co-60 irradiator, and the PUR-1 12 kW fission nuclear research reactor were utilized, respectively. Irradiation absorbed doses ranged from 1 to 100 kGy. Acetone bath temperature was varied from ~40 °C to ~54 °C. Results revealed a strong dependence of MLD on acetone bath temperature between neutron and gamma photon dose components; this allowed for the unique ability of PLAD to potentially perform as both a neutron-cum-gamma or as a gamma or neutron radiation dosimeter and intensity level detector. A linear trend is found for combined neutron and gamma radiation doses from 0 to 40 kGy when dissolution is conducted above 50 °C. The important potential ability to distinguish neutron from gamma radiation fields was scoped and found to be feasible by determining MLD at 45 °C. The potential was studied for simultaneous use as an in-core neutron and gamma monitor of an operating 3 GWt light-water reactor (LWR). Scoping tests were conducted with the pre-irradiated (@ 20 °C) PLAD resin beads followed by heating to in-core LWR coolant (300 °C) conditions for ~30 s corresponding to the time to reach ~40 kGy total doses in a typical 3 GWt LWR. MLD results were unaffected, indicating the exciting and unique potential for in situ (low-cost, accurate and rapid) simultaneous mapping of neutron and gamma radiation fluxes, related dosimetry, and fission power level monitoring.

 Artículos similares

       
 
Peng Xue, Qing Li and Guodong Fu    
Aiming at the current complex problem of the mechanized high-quality picking of tender tea buds, this paper designs a tender tea bud-picking manipulator. In the picking process, the quality of the petiole and leaf blade of the tender tea bud is crucial, ... ver más
Revista: Applied Sciences

 
Majid Aleyaasin    
In this paper, the vibration control of the multivariable model of rotor bearing systems is considered for investigation. Some simply structured controllers that can suppress vibrational disturbances are tested for their robustness via the H8 optimality ... ver más
Revista: Acoustics

 
Anna Rita Bernadette Cammerino, Michela Ingaramo and Massimo Monteleone    
The European Parliament has recently passed the ?Nature Recovery? law to restore degraded ecosystems and prevent natural disasters as part of its ?Biodiversity Strategy 2030? and ?Green Deal?. In this respect, wetlands can provide a wide range of ecosyst... ver más
Revista: Water

 
Okan Bulut, Guher Gorgun, Tarid Wongvorachan and Bin Tan    
Rapid guessing is an aberrant response behavior that commonly occurs in low-stakes assessments with little to no formal consequences for students. Recently, the availability of response time (RT) information in computer-based assessments has motivated re... ver más
Revista: Algorithms

 
Muhammad Alfian, Umi Laili Yuhana, Eric Pardede and Akbar Noto Ponco Bimantoro    
Assessment is one benchmark in measuring students? abilities. However, assessment results cannot necessarily be trusted, because students sometimes cheat or even guess in answering the questions. Therefore, to obtain valid results, it is necessary to sep... ver más
Revista: Information