Inicio  /  Instruments  /  Vol: 4 Par: 3 (2020)  /  Artículo
ARTÍCULO
TITULO

Off-Axis Characterisation of the CERN T10 Beam for low Momentum Proton Measurements with a High Pressure Gas Time Projection Chamber

S.B. Jones    
T.S. Nonnenmacher    
E. Atkin    
G.J. Barker    
A. Basharina-Freshville    
C. Betancourt    
S.B. Boyd    
D. Brailsford    
Z. Chen-Wishart    
L. Cremonesi    
A. Deisting    
A. Dias    
P. Dunne    
J. Haigh    
P. Hamacher-Baumann    
A. Kaboth    
A. Korzenev    
W. Ma    
P. Mermod    
M. Mironova    
J. Monroe    
R. Nichol    
J. Nowak    
W. Parker    
H. Ritchie-Yates    
S. Roth    
R. Saakyan    
N. Serra    
Y. Shitov    
J. Steinmann    
A. Tarrant    
M.A. Uchida    
S. Valder    
A.V. Waldron    
M. Ward and M.O. WasckoaddShow full author listremoveHide full author list    

Resumen

We present studies of proton fluxes in the T10 beamline at CERN. A prototype high pressure gas time projection chamber (TPC) was exposed to the beam of protons and other particles, using the 0.8 GeV/c momentum setting in T10, in order to make cross section measurements of low energy protons in argon. To explore the energy region comparable to hadrons produced by GeV-scale neutrino interactions at oscillation experiments, i.e., near 0.1 GeV of kinetic energy, methods of moderating the T10 beam were employed: the dual technique of moderating the beam with acrylic blocks and measuring scattered protons off the beam axis was used to decrease the kinetic energy of incident protons, as well as change the proton/minimum ionising particle (MIP) composition of the incident flux. Measurements of the beam properties were made using time of flight systems upstream and downstream of the TPC. The kinetic energy of protons reaching the TPC was successfully changed from ~0.3 GeV without moderator blocks to less than 0.1 GeV with four moderator blocks (40 cm path length). The flux of both protons and MIPs off the beam axis was increased. The ratio of protons to MIPs vary as a function of the off-axis angle allowing for possible optimisation of the detector to select the type of required particles. Simulation informed by the time of flight measurements show that with four moderator blocks placed in the beamline, (5.6 ± 0.1) protons with energies below 0.1 GeV per spill traversed the active TPC region. Measurements of the beam composition and energy are presented.

 Artículos similares

       
 
Md. Rafiqul Islam, Mehrdad Shahmohammadi Beni, Shigeki Ito, Shinichi Gotoh, Taiga Yamaya and Hiroshi Watabe    
Proton range monitoring and verification is important to enhance the effectiveness of treatment by ensuring that the correct dose is delivered to the correct location. Upon proton irradiation, different positron emitting radioisotopes are produced by the... ver más
Revista: Applied Sciences

 
César Jesús-Valls, Marc Granado-González, Thorsten Lux, Tony Price and Federico Sánchez    
Recently, we proposed a novel range detector concept named ASTRA. ASTRA is optimized to accurately measure (better than 1%) the residual energy of protons with kinetic energies in the range from tens to a few hundred MeVs at a very high rate of O(" role=... ver más
Revista: Instruments

 
Andrew K.H. Robertson, Andrew Lobbezoo, Louis Moskven, Paul Schaffer and Cornelia Hoehr    
With recent impressive clinical results of targeted alpha therapy using 225Ac, significant effort has been directed towards providing a reliable and sufficient supply of 225Ac to enable widespread using of 225Ac-radiopharmaceuticals. TRIUMF has begun pro... ver más
Revista: Instruments

 
Konrad P. Nesteruk, Luca Ramseyer, Tommaso S. Carzaniga and Saverio Braccini    
Accurate knowledge of the beam energy distribution is crucial for particle accelerators, compact medical cyclotrons for the production of radioisotopes in particular. For this purpose, a compact instrument was developed, based on a multi-leaf Faraday cup... ver más
Revista: Instruments

 
Philipp Häffner, Carolina Belver Aguilar, Saverio Braccini, Paola Scampoli and Pierre Alexandre Thonet    
The medical cyclotron at the Bern University Hospital (Inselspital) is used for both routine 18" role="presentation" style="position: relative;">1818 18 F production for Positron Emission Tomography (PET) and multidisciplinary research. It provides proto... ver más
Revista: Instruments