Redirigiendo al acceso original de articulo en 22 segundos...
Inicio  /  Buildings  /  Vol: 13 Par: 1 (2023)  /  Artículo
ARTÍCULO
TITULO

Experimental and Numerical Investigation of the Shear Performance of PSCC Shear Connectors with Poured UHPC

Fengli Zhou    
Chunwu Guo    
Jiangtao Zhang    
Jincen Guo    
Jinlong Jiang and Lulin Ning    

Resumen

Assembled steel-composite bridges generally use stud connectors to achieve the connection between the deck slab and the steel main girders. However, the commonly-used cluster studs weaken the integrity of the precast deck slabs and are not conducive to reducing the size of the precast deck slabs. Based on the excellent mechanical performance of UHPC, a precast steel-concrete composite bridge system consisting of precast bridge deck slabs, bonding cavities, and steel girders was proposed in this study. The system was named PSCC (Precast Steel-Concrete Connectors). To verify the applicability of PSCC connectors in engineering, push-out tests and finite element analysis were carried out in this paper to investigate the shear performance and influence parameters of PSCC connectors. The results showed that compared with the full bonding at the steel-UHPC interface, the shear bearing capacity of the specimens with 30% debonded area rate (the ratio of defect area to total interface area) and the shear bearing capacity of the specimens with 60% debonded area rate decreased by 0.35% and 9.74%, the elastic stiffness decreased by 14.86% and 21.72%, and the elastic-plastic stiffness decreased by 1.6% and 12.8%, respectively. When the steel-UHPC percentage of debonded area is less than 30%, the shear resistance of PSCC connectors is affected very little. However, when the steel-UHPC percentage of debonded area is 60%, the shear resistance of PSCC connectors is greatly affected. Therefore, adequate filling of the UHPC connection layer should be ensured in the project. In addition, the PSCC connectors have excellent ductility, their characteristic slip value Su" role="presentation" style="position: relative;">????Su S u is much higher than the EC4 specification of 6 mm, and they have better shear performance than conventionally installed stud connectors. According to the results of the parametric analysis, it was found that the failure mode of the PSCC connectors was shear reinforcement fracture when the area ratio of shear reinforcement to stud was less than 1.55, under the premise of the same material strength. On the contrary, the failure mode of PSCC connections was stud fracture. When the transverse spacing of both studs and shear reinforcement is 4d, the PSCC connectors can maintain a high ultimate load capacity while reducing the amount of UHPC in the bonding cavity. Therefore, 4d was chosen as the best spacing for both studs and shear reinforcement.

 Artículos similares

       
 
Gao Huang, Chengjun Qiu, Mengtian Song, Wei Qu, Yuan Zhuang, Kaixuan Chen, Kaijie Huang, Jiaqi Gao, Jianfeng Hao and Huili Hao    
Cavitation is typically observed when high-pressure submerged water jets are used. A composite nozzle, based on an organ pipe, can increase shear stress on the incoming flow, significantly enhancing cavitation performance by stacking Helmholtz cavities i... ver más
Revista: Water

 
Ziyi Wang, Jinqing Jia, Lihua Zhang and Ziqi Li    
The direct-shear test is the primary method used to test the shear strength of transparent soil, but this experiment is complex and easily influenced by experimental conditions. In order to simplify the process of obtaining the shear strength of transpar... ver más
Revista: Buildings

 
Matteo Dellacasagrande, Davide Lengani, Daniele Simoni and Marina Ubaldi    
The bursting phenomenon consists in the switch of a laminar separation bubble from a short to a long configuration. In the former case, reduced effects on profile pressure distribution are typically observed with respect to the attached condition. On the... ver más

 
Bora Pulatsu, Rhea Wilson, Jose V. Lemos and Neboj?a Mojsilovic    
Unreinforced masonry (URM) walls are common load-bearing structural elements in most existing buildings, consisting of masonry units (bricks) and mortar joints. They indicate a highly nonlinear and complex behaviour when subjected to combined compression... ver más
Revista: Infrastructures

 
Jie Liu, Xiangyu Huang, Juanjuan Chen and Qiaoyun Wu    
The excessive deflection of large-span cantilever cast prestressed concrete (LCCPC) box girders has always been a complex problem to be solved in bridge engineering. To analyze the effect of shear deformation at segmental joints on the deflection of LCCP... ver más
Revista: Buildings