Particle Image Velocimetry Measurements of the Flow-Diverting Effects of a New Generation of the eCLIPs Implant for the Treatment of Intracranial Bifurcation Aneurysms

Sina G. Yazdi    
Daniel Mercier    
Renee Bernard    
Adam Tynan and Donald R. Ricci    

Resumen

Flow diverters (FDs) for the endovascular treatment of intracranial aneurysms are effective for sidewall aneurysms, but their use at a bifurcation is problematic because FDs only partially cover the aneurysm neck and impede flow into a daughter branch; they are thus not employed routinely in this anatomy. eCLIPs was developed as a non-tubular implant to completely cover the neck of an aneurysm and serve as a coil retention device necessary for the adequate treatment of wide-neck bifurcation aneurysms. eCLIPs has shown some flow diversion effects in bifurcation anatomy but not equal to those exhibited by clinically accepted flow diverters in sidewall anatomy. A new generation of eCLIPs implant, the eCLIPs bifurcation flow diverter (eBFD), with higher metal coverage, was developed to achieve a similar flow diversion as a Pipeline Embolization Device (PED), a prototypical FD. Particle image velocimetry was used to capture the fluid dynamics and velocity reduction within silicone aneurysm replicas. A circulatory mimicking loop was developed to circulate the flow through the silicone models. All generations of eCLIPs implants had some flow-diverting effect, with increasing metal coverage density of the implant proportionately increasing the flow diversion effect. The eBFD, with a metal density of 35%, showed greater flow diversion than PED, with 30% metal density, for bifurcation anatomy. The eBFD showed similar reduction of flow in a bifurcation anatomy to PED in a sidewall, both sufficient to permit early thrombosis of the aneurysm. Thus, the eBFD can potentially provide sufficient flow diversion for the treatment of bifurcation aneurysms to avoid adjunctive coiling.

 Artículos similares

       
 
Luís P. N. Mendes, Ana M. C. Ricardo, Alexandre J. M. Bernardino and Rui M. L. Ferreira    
We present novel velocimetry algorithms based on the hybridization of correlation-based Particle Image Velocimetry (PIV) and a combination of Lucas?Kanade and Liu?Shen optical flow (OpF) methods. An efficient Aparapi/OpenCL implementation of those method... ver más
Revista: Water

 
Kedong Zhang, Wenhua Wang, Yihua Liu, Linlin Wang, Yazhen Du, Hongxia Li and Yi Huang    
A new type of anti-rolling device denoted as a fluid momentum wheel (FMW) is proposed to address the limitations of traditional gyrostabilizers in reducing the roll responses of floating platforms in waves. The proposed device is based on the same gyrosc... ver más

 
Eugene N. A. Hoffman, Elijah J. LaLonde, Angelina Andrade, Ivana Chen, Hayden A. Bilbo and Christopher S. Combs    
The characterization of a hypersonic impulse facility is performed using a variety of methods including Pitot probe scans, particle image velocimetry, and schlieren imaging to verify properties such as the velocity, Mach number, wall boundary layer thick... ver más
Revista: Aerospace

 
Liang Li, Ming Chen, Fang Wang, Zhichen Wu and Anan Xu    
In this work, the flow field of an autorotating rotor in a water tunnel with various pitches and shaft backward angles was investigated via particle image velocimetry (PIV). The experiments were carried out on a free-rotating two-bladed single rotor. Com... ver más
Revista: Aerospace

 
Rahmeh Ibrahim, Rawan Ghnemat and Qasem Abu Al-Haija    
Convolutional Neural Networks (CNNs) have exhibited remarkable potential in effectively tackling the intricate task of classifying MRI images, specifically in Alzheimer?s disease detection and brain tumor identification. While CNNs optimize their paramet... ver más
Revista: AI