Resumen
Fiber materials have advantages such as light weight and high strength, corrosion resistance, fatigue resistance, and easy processing and production, and they are widely applied in the repair and renovation of concrete structures. To promote the construction convenience of fiber materials, fiber raw yarn is continuously braided to form fiber-belt-bars. Based on the existing research, the performance of bonding between fiber-belt-bars and a concrete interface was investigated, and pull-out tests were performed to systematically investigate the effects of the fiber-belt-bar cross-sectional size, anchorage length, concrete strength, and fiber type on the bonding performance. The experimental results show that the bond strength reduces with an increase in the anchorage length, increase in cross-sectional size, and decrease in concrete strength, and the effect of fiber type on the bond strength is not obvious. On this basis, a formula for calculating the average bond strength of fiber-belt-bars is proposed. Experiments and calculations determined that the average bond strength between fiber-belt-bar and concrete with a cross-sectional size of 12 mm × 3 mm is 10?30% higher than that with a cross-sectional size of 20 mm × 3 mm for the same anchorage length. Finally, the minimum anchorage length of the fiber-belt-bar is proposed to provide a valuable reference for the use of fiber-belt-bar in concrete projects.