Effects of Osseodensification Protocols on Insertion Torques and the Resonance Frequency Analysis of Conical-Shaped Implants: An In Vitro Study on Polyurethane Foam Blocks

Nicola Pranno    
Francesca De Angelis    
Sara Giulia Fischetto    
Edoardo Brauner    
Mirko Andreasi Bassi    
Annalisa Marrapese    
Gerardo La Monaca    
Iole Vozza and Stefano Di Carlo    

Resumen

Bone density at the implant site is correlated to the success of osseointegration. The objective of this in vitro study was to evaluate the efficacy of osseodensification burs in increasing bone density using a solid polyurethane foam block model. The osseodensification burs kit was used to perform 48 osteotomies on a rigid polyurethane foam test ground. Burs were utilized on a TMM2 implant motor for data collection. The osteotomies were divided into two study groups (A and C) in which implant sites, extended 12 and 14 mm deep, respectively, were prepared using the drills to a compaction rotation; two control groups, B and D, represented the osteotomies for which the drills were used in cutting direction. A 3.8 × 12 mm conical implant was inserted into each site; for each implant, data were collected on the peak torque (Cp), mean torque (Cm), and integral depth curve (I). The implants underwent resonance frequency analysis (RFA) to assess the implant stability quotient (ISQ). Correlation analysis was performed between I, Cm, Cp and ISQ. One-way analysis of variance (ANOVA) was used to identify statistically significant differences between groups. Group C, representing osteotomies prepared at 14 mm with osseodensification burs, showed a significantly higher value for each parameter. Implants at sites obtained with osteocondensation drills and prepared at greater depth for autologous particle grafting showed significant increases in each implant stability parameter.

 Artículos similares

       
 
Dario Puljic, Asja Celebic, Ines Kovacic and Nikola Petricevic    
The new Ti?Zr (Roxolid®) mini-implants have not yet been fully researched. We analyzed peri-implant and posterior edentulous area microstrains during mandibular overdenture (OD) loading at different sites with different extents of forces when one-, two-,... ver más
Revista: Applied Sciences

 
Sholpan G. Giniyatova, Rafael I. Shakirzyanov, Yuriy A. Garanin, Nurzhan A. Sailaukhanov, Artem L. Kozlovskiy, Natalia O. Volodina, Dmitriy I. Shlimas and Daryn B. Borgekov    
Ceramics based on zirconium dioxide are very important compounds for dental, implant, and structural material applications. Despite the fact that tetragonally stabilized YSZ has been well studied, the search for new compositions of zirconia-based ceramic... ver más
Revista: Applied Sciences

 
Annika Schulz, Virgilia Klär, Tanja Grobecker-Karl and Matthias Karl    
Modern implant designs should allow for adequate primary stability but limit mechanical stress on buccal bone in order to prevent initial marginal bone loss. A dental implant characterized by a shift in core diameter and thread geometry was evaluated. Po... ver más
Revista: Applied Sciences

 
Ghada Alrabeah, Jonathan C. Knowles and Haralampos Petridis    
The improved peri-implant bone response demonstrated when utilizing the platform-switching concept may result from the reduced levels of metal ions released from implant?abutment surfaces to the surrounding tissues. These corrosion products may play a ma... ver más
Revista: Applied Sciences

 
Sven Kliesch, Josef Chalupper, Thomas Lenarz and Andreas Büchner    
Smartphones are increasingly being used to enable patients to play an active role in managing their own health through applications, also called apps. The latest generation of sound processors for cochlear implants offer Bluetooth connectivity that makes... ver más
Revista: Applied Sciences