Redirigiendo al acceso original de articulo en 24 segundos...
Inicio  /  Applied Sciences  /  Vol: 9 Par: 14 (2019)  /  Artículo
ARTÍCULO
TITULO

A Method for Calibrating a Digital Image Correlation System for Full-Field Strain Measurements during Large Deformations

Robert Blenkinsopp    
Jon Roberts    
Andy Harland    
Paul Sherratt    
Paul Smith and Tim Lucas    

Resumen

Numerous variables can introduce errors into the measurement chain of a digital image correlation (DIC) system. These can be grouped into two categories: measurement quality and the correlation principle. Although previous studies have attempted to investigate each error source in isolation, there are still no comprehensive, standardized procedures for calibrating DIC systems for full-field strain measurement. The aim of this study, therefore, was to develop an applied experimental method that would enable a DIC practitioner to perform a traceable full-field measurement calibration to evaluate the accuracy of a particular system setup in a real-world environment related to their specific application. A sequence of Speckle Pattern Boards (SPB) that included artificial deformations of the speckle pattern were created, allowing for the calibration of in-plane deformations. Multiple deformation stages (from 10% to 50%) were created and measured using the GOM ARAMIS system; the results were analysed and statistical techniques were used to determine the accuracy. The measured strain was found to be slightly over-estimated (nominally by 0.02%), with a typical measurement error range of 0.34% strain at a 95% confidence interval. Location within the measurement volume did not have a significant effect on error distributions. It was concluded that the methods developed could be used to calibrate a DIC system in-situ for full-field measurements of large deformations. The approach could also be used to benchmark different DIC systems against each other or allow operators to better understand the influence of particular measurement variables on the measurement accuracy.

Palabras claves

 Artículos similares

       
 
Abdelhafid El Alaoui El Fels, Laila Mandi, Aya Kammoun, Naaila Ouazzani, Olivier Monga and Moulay Lhassan Hbid    
The concept of using wastewater as a substitute for limited water resources and environmental protection has enabled this sector to make major technological advancements and, as a result, has given us an abundance of physical data, including chemical, bi... ver más
Revista: Water

 
Ryan Mendenhall and Babak Eslami    
Four-dimensional printing is a process in which a 3D-printed object is intentionally transformed in response to an external stimulus such as temperature, which is useful when the final geometry of a 3D-printed part is not easily manufacturable. One metho... ver más
Revista: Applied Sciences

 
Cong T. Nguyen, Ruslan D. Khlynov, Victoria A. Ryzhova, Alexey A. Gorbachev, Sergey N. Yarishev, Igor A. Konyakhin, Todor S. Djamiykov and Marin B. Marinov    
Theoretical aspects of methods for calibrating Stokes polarimeters are considered. The prospects and opportunities for implementing the presented methods for calibrating portable polarization systems used in biology and medicine are determined. Based on ... ver más
Revista: Computation

 
Ivar Annus, Anatoli Vassiljev, Nils Kändler and Katrin Kaur    
The purpose of the study was to present an automated module for the calibration of urban drainage system models. A prepared tool based on the Open Water Analytics toolkit included 12 additional calibration parameters as compared to the existing similar s... ver más
Revista: Water

 
Yanming Guo, Yan Bai, Shuaihe Gao, Zhibing Pan, Zibin Han, Decai Zou, Xiaochun Lu and Shougang Zhang    
An ultrahigh precise clock (space optical clock) will be installed onboard a low-orbit spacecraft (a usual expression for a low-orbit satellite operating on an orbit at an altitude of less than 1000 km) in the future, which will be expected to obtain bet... ver más
Revista: Information