Resumen
The passivation of zinc alloy coating was achieved through the utilization of both silicate and trivalent chromium passivation systems, employing a specific process formula consisting of Co(NO3)2 at a concentration of 2.5 g/L, C76H52O46 at 3 mL/L, Na2SiO3 at 25 g/L, C6H5Na3O7 at 15 g/L, and an appropriate amount of organic accelerator. The composite passivation of silicate and tannic acid was found to be more effective than the trivalent chromium passivation film, as it successfully eliminated the dendrite structure on the coating surface and reduced surface defects. The coordination between negatively charged SiO2- or SiO2 micelles and Zn2+ results in the formation of a passivation film that exhibits lower corrosion current and higher corrosion potential compared to the trivalent chromium passivation film. Additionally, the impedance test fitting results indicate that the silicate passivation film possesses a higher resistance value. Overall, the proposed silicate passivation system presents a viable alternative to the toxic chromate passivation system, offering non-toxicity and superior protective performance relative to the trivalent chromium passivation system.